Phased-array MRI of canine prostate using endorectal and endourethral coils
✍ Scribed by Andrew C. Yung; Ali Y. Oner; Jean-Michel Serfaty; Mark Feneley; Xiaoming Yang; Ergin Atalar
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 357 KB
- Volume
- 49
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A four‐channel phased array consisting of one surface coil, two endorectal coils, and one flexible endourethral loop coil was designed for MRI of the canine prostate. The endorectal coils provide high signal in the posterior region of the prostate, while the endourethral and surface coils are sensitive to the central and anterior regions of the prostate. Gel phantom experiments indicate that the proposed phased‐array configuration generates 15 times more signal‐to‐noise ratio (SNR) than a combination of two surface coils and one endorectal coil within the posterior region of the prostate; the performance of the two configurations is comparable near the anterior prostate surface. Ultimate intrinsic SNR (UISNR) analysis was used to compare the proposed phased array's performance to the best possible SNR for external coils. This analysis showed that the proposed phased array outperforms the best‐case external coil within the posterior and central regions of the prostate by up to 20 times. In canine experiments in vivo, high‐resolution fast spin‐echo (FSE) images of the prostate were obtained with a pixel size of 230 μm obtained in 3 min 12 s. The proposed phased‐array design potentially can be used to increase the accuracy of prostate cancer staging and the feasibility of MR‐guided prostate interventions. Magn Reson Med 49:710–715, 2003. © 2003 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To assess the accuracy of MRI, using a pelvic phased‐array coil and an endorectal coil, for preoperative local staging of rectal cancer. ## Materials and Methods Fifty‐one patients (26 males and 25 females) with adenocarcinoma of the rectum underwent preoperative MRI and s
## Abstract ## Purpose To demonstrate the feasibility of using a double loop phased array endorectal coil combined with a phased array body coil to image the prostate at 3T. ## Materials and Methods We designed and constructed a novel prostate coil employing two arrayed 4.0 × 5.0 cm loops, tuned
## Abstract We have designed a solid endorectal receiver coil for MRI of the prostate. The coil provided an improved signal‐to‐noise ratio up to 5 cm from its surface when compared with a standard pelvic phased array. This preliminary report describes 16 patients who were imaged using this coil, se
## Abstract A new method for efficiently processing MRS data acquired with phased‐array coils is presented. The method consists of performing phase compensation (i.e., redefining the signal phase relative to a common reference) of the signals in the time domain prior to combining the signals. The r