𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Phased-array MRI of canine prostate using endorectal and endourethral coils

✍ Scribed by Andrew C. Yung; Ali Y. Oner; Jean-Michel Serfaty; Mark Feneley; Xiaoming Yang; Ergin Atalar


Publisher
John Wiley and Sons
Year
2003
Tongue
English
Weight
357 KB
Volume
49
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A four‐channel phased array consisting of one surface coil, two endorectal coils, and one flexible endourethral loop coil was designed for MRI of the canine prostate. The endorectal coils provide high signal in the posterior region of the prostate, while the endourethral and surface coils are sensitive to the central and anterior regions of the prostate. Gel phantom experiments indicate that the proposed phased‐array configuration generates 15 times more signal‐to‐noise ratio (SNR) than a combination of two surface coils and one endorectal coil within the posterior region of the prostate; the performance of the two configurations is comparable near the anterior prostate surface. Ultimate intrinsic SNR (UISNR) analysis was used to compare the proposed phased array's performance to the best possible SNR for external coils. This analysis showed that the proposed phased array outperforms the best‐case external coil within the posterior and central regions of the prostate by up to 20 times. In canine experiments in vivo, high‐resolution fast spin‐echo (FSE) images of the prostate were obtained with a pixel size of 230 μm obtained in 3 min 12 s. The proposed phased‐array design potentially can be used to increase the accuracy of prostate cancer staging and the feasibility of MR‐guided prostate interventions. Magn Reson Med 49:710–715, 2003. © 2003 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Mouse MRI using phased-array coils
✍ Daniel Gareis; Tobias Wichmann; Titus Lanz; Gerd Melkus; Michael Horn; Peter M. 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 434 KB
Local staging of rectal cancer using com
✍ Servet Tatli; Koenraad J. Mortele; Elizabeth L. Breen; Ronald Bleday; Stuart G. 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 365 KB

## Abstract ## Purpose To assess the accuracy of MRI, using a pelvic phased‐array coil and an endorectal coil, for preoperative local staging of rectal cancer. ## Materials and Methods Fifty‐one patients (26 males and 25 females) with adenocarcinoma of the rectum underwent preoperative MRI and s

Prostate MR imaging at 3T with a longitu
✍ David Y. Kim; Mitchell D. Schnall; Mark A. Rosen; Thomas Connick 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 239 KB

## Abstract ## Purpose To demonstrate the feasibility of using a double loop phased array endorectal coil combined with a phased array body coil to image the prostate at 3T. ## Materials and Methods We designed and constructed a novel prostate coil employing two arrayed 4.0 × 5.0 cm loops, tuned

A solid reusable endorectal receiver coi
✍ Nandita M. Desouza; David J. Gilderdale; Rakesh Puni; Glyn A. Coutts; Ian R. You 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 469 KB 👁 1 views

## Abstract We have designed a solid endorectal receiver coil for MRI of the prostate. The coil provided an improved signal‐to‐noise ratio up to 5 cm from its surface when compared with a standard pelvic phased array. This preliminary report describes 16 patients who were imaged using this coil, se

Time-domain combination of MR spectrosco
✍ Mark A. Brown 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 305 KB

## Abstract A new method for efficiently processing MRS data acquired with phased‐array coils is presented. The method consists of performing phase compensation (i.e., redefining the signal phase relative to a common reference) of the signals in the time domain prior to combining the signals. The r