## Abstract ## Purpose: To investigate the feasibility of perfusion imaging using an arterial spin labeling (ASL) technique for breast cancer. ## Materials and Methods: Thirteen female patients with primary breast cancers were included in this study. All examinations were performed on 1.5 Tesla
Perfusion imaging of the pancreas using an arterial spin labeling technique
✍ Scribed by Christina Schraml; Nina F. Schwenzer; Petros Martirosian; Claus D. Claussen; Fritz Schick
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 325 KB
- Volume
- 28
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To investigate the feasibility of perfusion imaging of the pancreas using an arterial spin labeling (ASL) technique.
Materials and Methods
An adapted flow‐sensitive alternating inversion recovery (FAIR)‐TrueFISP ASL technique was implemented on a 1.5T scanner. Anatomical and perfusion imaging in three different parts of the pancreas were performed in 10 healthy volunteers. Quantitative perfusion values were calculated using the extended Bloch equations.
Results
Perfusion images of all subjects showed diagnostic image quality in the pancreatic tail and the head. Assessment of pancreatic tissue perfusion was possible in all organ parts. Mean perfusion values were 271 ± 79 mL/100g/min in the head, 351 ± 112 mL/100g/min in the body, and 243 ± 55 mL/100g/min in the tail of the pancreas. Total examination time for perfusion imaging of the entire organ was 15.4 minutes.
Conclusion
FAIR‐TrueFISP permits analysis of pancreatic tissue perfusion with good image quality in a clinically applicable measuring time. Assessment of perfusion disorders may be useful in the diagnosis of inflammatory pancreatic pathologies, endocrine and exocrine pancreatic disorders, and in monitoring of pancreatic transplants. J. Magn. Reson. Imaging 2008;28:1459–1465. © 2008 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
Recently, a technique based on arterial spin labeling, called dynamic arterial spin labeling (DASL (Magn Reson Med 1999;41:299-308)), has been introduced to measure simultaneously the transit time of the labeled blood from the labeling plane to the exchange site, the longitudinal relaxation time of
## Abstract Arterial spin labeling is a noninvasive technique that can quantitatively measure cerebral blood flow. While traditionally arterial spin labeling employs 2D echo planar imaging or spiral acquisition trajectories, single‐shot 3D gradient echo and spin echo (GRASE) is gaining popularity i
## Abstract Magnetic resonance ventilation‐perfusion (V/Q) imaging has been demonstrated using oxygen and arterial spin labeling techniques. Inhaled oxygen is used as a paramagnetic contrast agent in ventilation imaging using a multiple inversion recovery (MIR) approach. Pulmonary perfusion imaging
We describe here experimental considerations in the implementation of quantitative perfusion imaging techniques for functional MRI using pulsed arterial spin labeling. Three tagging techniques: EPISTAR, PICORE, and FAIR are found to give very similar perfusion results despite large differences in st