𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Performance of toughness indices for steel fiber reinforced shotcrete

✍ Scribed by Fushu Jeng; Ming-Lang Lin; Shih-Che Yuan


Book ID
104347493
Publisher
Elsevier Science
Year
2002
Tongue
English
Weight
557 KB
Volume
17
Category
Article
ISSN
0886-7798

No coin nor oath required. For personal study only.

✦ Synopsis


To indicate the flexural toughness of Steel Fiber Reinforced Concrete or Shotcrete SFRC or SFRS , several indices have been developed and some of them are now national standards. Whether these indices can properly indicate the actual toughness of sprayed shotcrete is of concern. This paper aims at assessing the performance of the indices for a variety of SFRS sprayed at job site, instead of being cast in laboratory. The mixture actually sprayed, especially the steel fiber content, may differ from the mixture before spraying and this inherently affects the toughness of SFRS, therefore, counting of steel fiber over the fracture surface of a tested beam was conducted. This is helpful in interpreting the experimental results. The indices evaluated include:

Ε½ . Ε½ . Ε½ . toughness index I ; residual strength factor R ; equivalent flexural strength f ; and the indices based on the residual flexure e stress method, including a Norwegian index, f, and a proposed relative residual stress factor f . The experimental results reveal m that increases of steel fiber content cement content, silica fume content, and the aspect ratio of the steel fibers improve the toughness of SFRS. The performance of the indices is evaluated on the basis of the following factors: independence with regard to the testing machine as well as sufficient sensitivity to the ingredients of SFRS. The results of evaluation indicate that the indices based on the residual flexural stress method, and involving greater deflection, tend to perform better in indicating the toughness of SFRS.


πŸ“œ SIMILAR VOLUMES


Toughness indices of steel fiber reinfor
✍ Nemkumar Banthia; Moussa Mani πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 640 KB

This paper presents some micromechanical and macromechanical test data for steel fiber reinforced concrete at normal (22Β°C) and at low (-50Β°C) temperatures. Micromechanical tests were in the form of fiber pull-out tests with the fiber aligned in the direction of the applied pull-out load. In the mac

Fracture toughness of steel-fiber-reinfo
✍ Kotha, S. P. ;Li, C. ;Schmid, S. R. ;Mason, J. J. πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 255 KB

## Abstract Fractures in the bone‐cement mantle (polymethyl methacrylate) have been linked to the failure of cemented total joint prostheses. The heat generated by the curing bone cement has also been implicated in the necrosis of surrounding bone tissue, leading to loosening of the implants. The a

Fracture toughness of a short-fiber rein
✍ W. E. Haskell III; S. P. Petrie; R. W. Lewis πŸ“‚ Article πŸ“… 1983 πŸ› Society for Plastic Engineers 🌐 English βš– 472 KB

## Abstract Thin plates of carbon short‐fiber reinforcement polycarbonate were injection molded. The mold was designed to produce a uniform melt flow across the cavity and an extended knock‐out pin was incorporated to form a circular hole at the center of the molded plate. The elastic constants of

Determination of the first-crack strengt
✍ S. Mindess; L. Chen; D.R. Morgan πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 718 KB

The first-crack strength and flexural toughness of steel fiber-reinforced concrete specimens containing different volumes of steel fibers (0 to 1.5%) were determined using the procedures outlined in ASTM C1018, and the ASTM toughness indices were calculated. It was found that the value of the first-

Use of steel fiber reinforced mortar for
✍ Tuğçe Sevil; Mehmet Baran; Turhan Bilir; Erdem Canbay πŸ“‚ Article πŸ“… 2011 πŸ› Elsevier Science 🌐 English βš– 688 KB

The objective of this research was to develop an economical, structurally effective, and practically applicable steel fiber reinforced mortar (SFRM) which could be applied onto the hollow brick infills of a reinforced concrete (RC) structure. Masonry walls were almost converted into strong and rigid