𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Performance improvement of a two-stage GM cryocooler by use of Er(Ni0.075Co0.925)2 magnetic regenerator material

✍ Scribed by L Trevisani; T Kuriyama; F Negrini; T Okamura; Y Ohtani; M Okamura; M Fabbri


Publisher
Elsevier Science
Year
2002
Tongue
English
Weight
357 KB
Volume
42
Category
Article
ISSN
0011-2275

No coin nor oath required. For personal study only.

✦ Synopsis


A newly developed magnetic regenerator material Er(Ni 0:075 Co 0:925 ) 2 , having high specific heat at temperatures from 10 to 20 K, has been tested inside the second regenerator of a two-stage GM cryocooler. Different working conditions have been examined: four Er(Ni 0:075 Co 0:925 ) 2 /Pb material ratios, three displacer reciprocating speeds, and two cryocooler stroke lengths. In the best working conditions, the experimental results show a cooling power improvement up to 15% over the whole temperature range from 10 to 20 K compared to that of the same GM cryocooler employing only lead.