Pencil Lead Electrode Modified with Hemoglobin Film as a Novel Biosensor for Nitrite Determination
โ Scribed by Majidi, Mir Reza; Saadatirad, Afsaneh; Alipour, Esmaeel
- Book ID
- 120518934
- Publisher
- John Wiley and Sons
- Year
- 2013
- Tongue
- English
- Weight
- 396 KB
- Volume
- 25
- Category
- Article
- ISSN
- 1040-0397
No coin nor oath required. For personal study only.
โฆ Synopsis
Abstract
In the present paper, the electrochemical reduction of nitrite at a hemoglobin modified pencil lead electrode (Hb/PLE) is described. The electrochemical properties of nitrite were studied by cyclic voltammetry and chronoamperometry. Results showed that the hemoglobin film has an excellent electrochemical activity towards the reduction of nitrite. By using voltammetric and chronoamperometric methods, ฮฑ, n~ฮฑ~ and n were calculated. Then the ability of the electrode for nitrite determination was investigated using differential pulse voltammetry. The electrocatalytic reduction peak currents were found to be linear with the nitrite concentration in the range from 10 to 220โ ยตM with a detection limit of 5โ ยตM. The relative standard deviation is 2โ% for 3 successive determinations of a 100โ ยตM nitrite solution. This modified electrode was successfully used for the detection of low amounts of NO~2~^โ^ in spinach sample and a spiked sample of tap water.
๐ SIMILAR VOLUMES