๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Partial discharges in liquid-nitrogen impregnated, taped-cable insulation

โœ Scribed by Rigby, S.J.; Weedy, B.M.


Book ID
119747582
Publisher
Institution of Electrical Engineers
Year
1976
Weight
754 KB
Volume
123
Category
Article
ISSN
0020-3270

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Liquid nitrogen impregnated insulation f
โœ M. Fukasawa; H. Nagano ๐Ÿ“‚ Article ๐Ÿ“… 1974 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 394 KB

The measured dissipation factor and breakdown strength of liquid nitrogen impregnated polyethylene paper insulation for cryogenic power cable are presented. The effect of screening, and impulse and ac deteriorations are discussed. The tests were carried out using model cable type specimens.