An intrinsic criterion was derived for parametric sensitivfty and r-way in co-currently cooled tubular reactors. It is essentially based on the approach of Van WelseMere and Froment (1970) developed for the constant wall temperature case and which-makes use of fundamental properties of the trajector
Parametric sensitivity in tubular reactors with co-current external cooling
โ Scribed by Evan Bauman; Arvind Varma; Jean Lorusso; Mario Dente; Massimo Morbidelli
- Publisher
- Elsevier Science
- Year
- 1990
- Tongue
- English
- Weight
- 596 KB
- Volume
- 45
- Category
- Article
- ISSN
- 0009-2509
No coin nor oath required. For personal study only.
โฆ Synopsis
The parametric sensitivity behavior of a tubular reactor with co-current external cooling is investigated using a generalized parametric sensitivity criterion. This criterion is based on the occurrence of a maximum value for the normalized sensitivity of the hot-spot with respect to any of the input parameters of the reactor. Comparisons are made with the Adler and Enig criterion, which is based on a geometric feature of the temperature profile; this criterion is shown to give qualitatively erroneous results in some cases. The regions of parametric sensitivity in the reactor parameter space are also reported for various values of the involved dimensionless parameters.