PARACEST MRI with improved temporal resolution
β Scribed by Guanshu Liu; M. Meser Ali; Byunghee Yoo; Mark A. Griswold; Jean A. Tkach; Mark D. Pagel
- Book ID
- 102956454
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 506 KB
- Volume
- 61
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
PARAmagnetic Chemical Exchange Saturation Transfer (PARACEST) is a novel contrast mechanism for MRI. A PARACEST MRI methodology with high temporal resolution is highly desired for in vivo MRI applications of molecular imaging. To address this need, a strategy has been developed that includes a long selective saturation period before each repetition of a Rapid Acquisition with Relaxation Enhancement (RARE) pulse sequence. This strategy is suitable for the application of PARACEST contrast agents to environments with long T~1~ relaxation times. An alternative strategy uses short selective saturation periods before the acquisition of each kβspace trajectory to maintain steady state conditions, which can be implemented with a Fast Low Angle Shot (FLASH) pulse sequence. These short saturation periods lengthen the total scan time as compared to the first approach but compensate for the loss in PARACEST contrast related to T~1~ relaxation. Both approaches have been demonstrated in vitro and in vivo with significantly improved temporal resolutions as compared to a conventional gradientβecho PARACEST method without sacrificing CNR efficiency. These demonstrations also adopted a strategy for measuring the PARACEST effect that only requires selective saturation at a single MR frequency, which further improves temporal resolution for PARACEST detection. Magn Reson Med 61:399β408, 2009. Β© 2009 WileyβLiss, Inc.
π SIMILAR VOLUMES
## Abstract A novel method for reconstructing MRI temperature maps from undersampled data is presented. The method, model predictive filtering, combines temperature predictions from a preidentified thermal model with undersampled __k__βspace data to create temperature maps in near real time. The mo
## Abstract In fMRI, images can be collected in a very short time; therefore, high temporal resolution is possible in principle. However, the temporal resolution is limited by a blurred intrinsic hemodynamic response and a finite signalβtoβnoise ratio. To determine the upper limit of temporal resol
## Abstract In some dynamic imaging applications, only a fraction, 1/__n__, of the field of view (FOV) may show considerable change during the motion cycle. A method is presented that improves the temporal resolution for a dynamic region by a factor, __n__, while maintaining spatial resolution at a