Oxygen transfer and axial dispersion in an aeration tower containing static mixers

✍ Scribed by G. T. Maclean; L. E. Erickson; K. H. Hsu; L. T. Fan


Publisher
John Wiley and Sons
Year
1977
Tongue
English
Weight
443 KB
Volume
19
Category
Article
ISSN
0006-3592

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Oxygen transfer from gas to liquid under steady‐state cocurrent flow conditions was modeled using the dispersion model, and the oxygen transfer coefficients were estimated from available data for a column with Koch motionless mixers. The dispersion in the column was estimated for several different gas and liquid flow rates using steady‐state tracer experiments. The estimated oxygen transfer coefficients were compared with those estimated using complete mixing and plug flow models. The results indicate that the dispersion model is the most appropriate model for estimating the mass transfer coefficient from the available data.