๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Optimum distribution of water-wall thickness in a transwall

โœ Scribed by M. Upadhya; G.N. Tiwari; S.N. Rai


Publisher
Elsevier Science
Year
1991
Tongue
English
Weight
361 KB
Volume
17
Category
Article
ISSN
0378-7788

No coin nor oath required. For personal study only.

โœฆ Synopsis


In this communication, a transient analysis of a transwall for an air-conditioned room is presented. An analytical expression for the thermal flux entering the air-conditioned room through direct and indirect gain is derived in terms of the physical properties of the transwall as well as the climatic parameters. The water temperatures and the flux entering the room are computed on an hourly basis for a number of days for the typical cold climatic conditions of Srinagar. On the basis of the numerical results, it is observed that: (i) steady-state conditions are achieved after the third day; and (ii) the maximum thermal flux is achieved for ~L= ~Lw1/~ZLw = 1.