## Abstract Most traditional methods for __T__~1~ map estimation in MRI with fast low‐angle‐shot sequences are aimed at high efficiency by compromising the fitting accuracy. In this paper, the __fundamental__ problem of parameter estimation in fast low‐angle‐shot MRI was re‐examined, and an accurat
Optimizing the precision in T1 relaxation estimation using limited flip angles
✍ Scribed by Henry Z. Wang; Stephen J. Riederer; James N. Lee
- Book ID
- 102952127
- Publisher
- John Wiley and Sons
- Year
- 1987
- Tongue
- English
- Weight
- 843 KB
- Volume
- 5
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
In this article we describe the precision in the estimation of the spin-lattice relaxation time T1 from MRI signals acquired for various flip angles with the repetition time TR held constant. We review the estimation procedure itself and present a model for the propagation of noise in the signal into the calculated T1. This model is verified by both Monte Carlo simulations and experimental data taken on image phantoms. Based on this model, we find that for a given TR/T1 there exist two optimal flip angles that will minimize the uncertainty in the estimated T1. We also show how two optimal angles can be selected for a given range of TR/T1 values. In addition, T1 estimation using the two optimal angles can be comparable to or better than using multiple evenly spaced angles. Finally, in an initial comparison with the two-point saturation recovery method of calculating T1, results for equal total scanning time TRTot suggest that for T1 greater than 0.5 TRTot, the limited flip angle approach gives better T1 precision whereas for T1 less than 0.5 TRTot the saturation recovery approach is better.
📜 SIMILAR VOLUMES
## Abstract Rapid 3D mapping of __T__~1~ relaxation times is valuable in diverse clinical applications. Recently, the variable flip angle (VFA) spoiled gradient recalled echo approach was shown to be a practical alternative to conventional methods, providing better precision and speed. However, the
## Abstract ## Purpose To present an evaluation method for three‐dimensional Look‐Locker (3D‐LL) based T1 quantification, calculating correct T1 values independent of local flip angle (FA) variations. The method was evaluated both in phantoms and in vivo in a delayed Gadolinium Enhanced MRI of Car
19Fluorine NMRS has the potential to enable noninvasive predictions of tumor response to 5-fluorouracil (5FU) therapy based on tumor pharmacokinetics. Knowledge of the T1's of 5FU and its fluoronucleotide anabolites (FNuc) is required for quantitative spectral analysis and selection of optimal pulse