𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Optimizing brain tissue contrast with EPI: A simulated annealing approach

✍ Scribed by Vasiliki N. Ikonomidou; Peter van Gelderen; Jacco A. de Zwart; Masaki Fukunaga; Jeff H. Duyn


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
781 KB
Volume
54
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A new magnetization preparation and image acquisition scheme was developed to obtain high‐resolution brain images with optimal tissue contrast. The pulse sequence was derived from an optimization process using simulated annealing, without prior assumptions with regard to the number of radiofrequency (RF) pulses and flip angles. The resulting scheme combined two inversion pulses with the acquisition of three images with varying contrast. The combination of the three images allowed separation of gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) based on T~1~, contrast. It also enabled the correction of small errors in the initial T~1~ estimates in postprocessing. The use of three‐dimensional (3D) sensitivity‐encoded (SENSE) echo‐planar imaging (EPI) for image acquisition made it possible to achieve a 1.15^3^ mm^3^ isotropic resolution within a scan time of 10 min 21 s. The cortical GM signal‐to‐noise ratio (SNR) in the calculated GM‐only image varied between 30 and 100. The novel technique was evaluated in combination with blood oxygen level‐dependent (BOLD) functional magnetic resonance imaging (fMRI) on human subjects, and provided for excellent coregistration of anatomical and functional data. Magn Reson Med 54:373–385, 2005. Published 2005 Wiley‐Liss, Inc.