Three-dimensional (3Dl fast spin-echo (FSE) imaging can produce contiguous thin sections for high-quality multiplanar reconstructions. Such reformatted images may be useful in the evaluation of three-dimensionally complex. curvilinear anatomic structures such as the hippocampus. The authors describe
Optimization of three-dimensional T1-weighted gradient-echo imaging of the cervical spine
✍ Scribed by Jeffrey S. Ross; Jean A. Tkach; John Dillinger; Paul M. Ruggieri; Thomas J. Masaryk; Michael T. Modic
- Publisher
- John Wiley and Sons
- Year
- 1992
- Tongue
- English
- Weight
- 692 KB
- Volume
- 2
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Various parameters of the three‐dimensional (3D) T1‐weighted magnetization‐prepared rapid acquisition gradient‐echo (MP‐RAGE) sequence were evaluated to improve spatial resolution while maintaining T1 contrast and a short examination time in imaging of the cervical spine in volunteers. The most dramatic improvements in image resolution occurred by decreasing section thickness to 1.2 mm and increasing the in‐plane matrix to 192 × 256, with a 230‐mm field of view. The increase in imaging time due to the increased matrix was offset by the elimination of the preparation pulse and wait time, without dramatic changes in contrast‐tonoise ratio or overall image quality. Optimum parameters included elimination of the preparation pulse and wait time, 12° flip angle, 192 × 256 matrix, 1.2‐mm section thickness, nonselective excitation (coronal acquisition), RF spoiling, and standard k‐space ordering, for an examination time of 5 minutes 21 seconds.
📜 SIMILAR VOLUMES
## Abstract By using a theoretical model, the signal difference‐to noise ratios between simulated lesions and normal white matter and gray matter were calculated as a function of lesion concentration of gadopentetate dimeglumine (GD) for two‐dimensional (2D) T1‐weighted spin‐echo (SE), three‐dimens
## Abstract ## Purpose To compare the __i__terative __d__ecomposition of water and fat with __e__cho __a__symmetry and __l__east‐squares estimation (IDEAL) method with fat‐saturated T1‐weighted (T~1~W) and T~2~W fast spin‐echo (FSE) and short‐TI inversion recovery (STIR) imaging of the brachial pl
## Abstract ## Purpose: To evaluate which T1‐wieghted technique between 3D gradient‐echo (FSPGR) and conventional spin‐echo (SE) sequence is more sensitive predictor of neurobehavioral dysfunction found in welders with chronic manganese (Mn) acquired at 3 Tesla. ## Materials and Methods: Forty‐t
## Abstract ## Purpose To evaluate the use of three‐dimensional (3D) gradient‐echo (GRE) magnetic resonance imaging (MRI) for percutaneous MR‐guided catheter placement for laser therapy of liver metastases. ## Materials and Methods Thirty‐four patients were included. A total of 122 MR‐guided per