## Abstract The chemometrics approach was applied for the separation optimization of flavonoid markers (quercetin, hesperetin and chrysin) in honey using micellar liquid chromatography (MLC). The investigated method combines SPE of flavonoids from honey using C~18~ cartridge and their separation an
Optimization of the Separation of Quinolines in Micellar Liquid Chromatography by Experimental Design and Regression Models
✍ Scribed by M. R. HADJMOHAMMADI; K. KAMEL
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 111 KB
- Volume
- 26
- Category
- Article
- ISSN
- 0256-7660
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The chemometrics approach was applied to the optimization of separation of quinolines in micellar liquid chromatography (MLC). The effect of four experimental parameters on chromatographic retention time was investigated by means of multivariate analysis. The factors considered were the concentration of sodium dodecyl sulfate (SDS), the organic modifier concentration and the length of its alkyl chain, and pH of the mobile phase. The experiments were performed according to a face centered cube response surface experimental design. In order to optimize the separation a Pareto‐optimality method was employed. The models were verified, because a good agreement was observed between the predicted and experimental values of the chromatographic response function in the optimal condition. The obtained regression models were characterized by both descriptive and predictive ability
(R^2^≥0.97 and R~CV~^2^≥0.92) and allowed the chromatographic separation of the quinolines with a good resolution and a total analysis time of 50 min.