Elution curves in ionic exchange chromatography (IEC) for a three-protein mixture (alpha-lactoalbumin, ovalbumin, and beta-lactoglobulin), carried out under different flow rates and ionic strength conditions, were simulated using two different mathematical models. These models were the Plate Model a
Optimization of hydrophobic interaction chromatography using a mathematical model of elution curves of a protein mixture
✍ Scribed by María Elena Lienqueo; Carolina Shene; Juan Asenjo
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 423 KB
- Volume
- 22
- Category
- Article
- ISSN
- 0952-3499
- DOI
- 10.1002/jmr.927
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
This paper describes a methodology for optimizing performance of hydrophobic interaction chromatography (HIC) for protein mixtures in which Rate Model simulations and evaluation of cost function are used. The system under study was HIC of a two‐protein mixture (α‐chymotrypsin and α‐amylase), carried out with different conditions (gradient steepness, salt, concentration, volume of sample, pH, type of matrix, and flow rates). Parameters in the rate model were obtained from different sources. Mass transfer parameters (Reynolds, Peclet, and Biot numbers) were calculated using empirical correlations. Under the experimental conditions Re number was small (0.23) and axial dispersion negligible (Pe~L~ > 300). Mass transfer was controlled by intraparticle diffusion (Bi > 50). The model assumes that equilibrium constant (b) in the Langmuir isotherm was salt concentration (I) dependent [b(I)]. Parameters in the relationship for b(I) were estimated from experimental single protein elution curves and used to simulate protein mixtures. Rate model simulations showed that if protein sample load to the column was below 1 mg, displacement effects were negligible; in other cases protein interactions would limit the proposed mathematical description of HIC. The calibrated Rate Model successfully predicted elution curves of the protein mixture with deviations lower than 6 × 10^−4^ absorbance units. The model was also able to predict that the Butyl Sepharose—NaCl 4 M system allowed to obtain the highest resolution (>1) for the two‐protein mixture evaluated. The cost function built for optimizing the performance of HIC considers yield, purity, concentration, and the time needed to accomplish the separation. This function contains two types of parameters that have to be determined. The ones dependent on the HIC system and process conditions were obtained from simulations of elution curves of the two‐protein mixture, by the calibrated Rate Model. The other parameters are dependent on characteristic and quality of the protein product; these were assumed for illustration purpose. Minimization of the cost function allows determination of flow rate, gradient steepness, and the fraction of eluted peak that has to be collected. Novelty of the present work is in showing how parameters in the fundamentally based Rate Model for HIC can be calibrated and how simulations can be used for the optimization of process conditions for the separation of a protein mixture. Copyright © 2008 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract Protein elution curves in ion exchange chromatography (IEC) were simulated with a rate model. Three pure proteins and their mixture were used (α‐lactalbumin, BSA, and conalbumin) under different operational conditions. The anionic matrix Q‐Sepharose FF was used packed in a 1 mL column.
## Abstract The behavior of a series of pure proteins partitioned in aqueous two‐phase systems is compared with their behavior during mild hydrophobic interaction chromatography (HIC). A simple theoretical rationale for this comparison is presented based upon solvophobic theory. Similarities were f
The success and validity of gene therapy and DNA vaccination in in vivo experiments and human clinical trials depend on the ability to produce large amounts of plasmid DNA according to defined specifications. A new method is described for the purification of a cystic fibrosis plasmid vector (pCF1-CF