## Abstract ## Purpose To compare an optimized water selective balanced steady‐state free precession sequence (WS‐bSSFP) with conventional magnetic resonance (MR) sequences in imaging cartilage of osteoarthritic knees. ## Materials and Methods Flip angles of sagittal and axial WS‐bSSFP sequences
Optimization of a dual echo in the steady state (DESS) free-precession sequence for imaging cartilage
✍ Scribed by Peter A. Hardy; Michael P. Recht; David Piraino; David Thomasson
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 875 KB
- Volume
- 6
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Three‐dimensional (3D) MR imaging of the knee is useful to detect cartilage abnormalities, although the tissue contrast in 3D gradient‐recalled echo (GRE) sequences such as gradient‐recalled acquisition in the steady state (GRASS) or fast low‐angle shot (FLASH) is poor. T2 contrast can be added to a GRASS sequence by combining the signals from the first and second gradient echoes, which form immediately after and immediately before each radiofrequency (RF) pulse in a 3D GRE sequence. We have optimized a 3D dual echo in the steady state (DESS) sequence, which produces one averaged image from the two echoes, for use in the detection of articular cartilage abnormalities. In the optimization process, we examined the imaging parameters of flip angle (α), repetition time (TR), echo time (TE), and bandwidth to maximize the contrast between cartilage and joint fluid. A theoretical simulation of the sequence was confirmed with experiments conducted on phantoms with known T1 and T2. On the basis of theoretical predictions and experiments using healthy volunteers, we determined that an optimized sequence with a bandwidth of 98 Hz per pixel, a TR of 30 msec, a TE of 7.1 msec, and an α of 60° produced the highest contrast between cartilage and fluid within a defined acquisition time of 6 minutes. Additional contrast was obtained by filtering the second‐echo image to eliminate noise before adding it to the first‐echo image.
📜 SIMILAR VOLUMES
## Abstract ## Purpose: To evaluate the performance of a slice navigator sequence integrated into a b‐SSFP sequence for obtaining real time respiratory self‐gated whole heart cine imaging. ## Materials and Methods: In this work, we present a novel and robust approach for respiratory motion detec
## Abstract ## Purpose To determine the correlation function between the steady‐state free precession (SSFP) and fast gradient echo (FGRE) cine MRI pulse sequences for measuring the myocardial mass and volumes. ## Materials and Methods Cardiac cine MRI examinations were acquired in 50 individual
## Abstract In this study we assessed the use of a steady state free precession (SSFP) cine sequence in a series of radially orientated long axis slices for the measurement of left ventricular volumes and mass. We validated the radial long axis approach in phantoms and ex vivo porcine hearts and ap
## Abstract ## Purpose To evaluate a new isotropic 3D proton‐density, turbo‐spin‐echo sequence with variable flip‐angle distribution (PD‐SPACE) sequence compared to an isotropic 3D true‐fast‐imaging with steady‐state‐precession (True‐FISP) sequence and 2D standard MR sequences with regard to the n