𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Optimization and validation of methods for mapping of the radiofrequency transmit field at 3T

✍ Scribed by Antoine Lutti; Chloe Hutton; Jürgen Finsterbusch; Gunther Helms; Nikolaus Weiskopf


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
564 KB
Volume
64
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


MRI techniques such as quantitative imaging and parallel transmit require precise knowledge of the radio-frequency transmit field (). Three published methods were optimized for robust mapping at 3T in the human brain: three-dimensional (3D) actual flip angle imaging (AFI), 3D echo-planar imaging (EPI), and two-dimensional (2D) stimulated echo acquisition mode (STEAM). We performed a comprehensive comparison of the methods, focusing on artifacts, reproducibility, and accuracy compared to a reference 2D double angle method. For the 3D AFI method, the addition of flow-compensated gradients for diffusion damping reduced the level of physiological artifacts and improved spoiling of transverse coherences. Correction of susceptibility-induced artifacts alleviated image distortions and improved the accuracy of the 3D EPI imaging method. For the 2D STEAM method, averaging over multiple acquisitions reduced the impact of physiological noise and a new calibration method enhanced the accuracy of the maps. After optimization, all methods yielded low noise maps (below 2 percentage units), of the nominal flip angle value (p.u.) with a systematic bias less than 5 p.u. units. Full brain coverage was obtained in less than 5 min. The 3D AFI method required minimal postprocessing and showed little sensitivity to off-resonance and physiological effects. The 3D EPI method showed the highest level of reproducibility. The 2D STEAM method was the most time-efficient technique. Magn Reson Med, 2010. © 2010 Wiley-Liss, Inc.


📜 SIMILAR VOLUMES


Actual flip-angle imaging in the pulsed
✍ Vasily L. Yarnykh 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 650 KB

## Abstract A new method has been developed for fast image‐based measurements of the transmitted radiofrequency (RF) field. The method employs an actual flip‐angle imaging (AFI) pulse sequence that consists of two identical RF pulses followed by two delays of different duration (TR~1~ < TR~2~). Aft

Error reduction and parameter optimizati
✍ M. Zaitsev; S. Steinhoff; N.J. Shah 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 348 KB

## Abstract A methodology is presented for the reduction of both systematic and random errors in __T__~1~ determination using TAPIR, a Look‐Locker‐based fast __T__~1~ mapping technique. The relations between various sequence parameters were carefully investigated in order to develop recipes for cho

Optimization and validation of a fully-i
✍ Daniel R. Messroghli; Andreas Greiser; Mirko Fröhlich; Rainer Dietz; Jeanette Sc 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 614 KB

## Abstract ## Purpose To optimize and validate a fully‐integrated version of modified Look‐Locker inversion‐recovery (MOLLI) for clinical single‐breathhold cardiac T1 mapping. ## Materials and Methods A MOLLI variant allowing direct access to all pulse sequence parameters was implemented on a 1

High-resolution T1 mapping of the brain
✍ Sean C.L. Deoni 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 472 KB

## Abstract ## Purpose To investigate an alternative approach to correct for flip angle inaccuracies in the driven equilibrium single pulse observation of T1 (DESPOT1) T1 mapping method. ## Materials and Methods While DESPOT1 is a robust method for rapid whole‐brain voxelwise mapping of the long

A model for radiofrequency electromagnet
✍ Alfred Bürgi; Patrizia Frei; Gaston Theis; Evelyn Mohler; Charlotte Braun-Fahrlä 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 187 KB 👁 2 views

## Abstract We present a geospatial model to predict the radiofrequency electromagnetic field from fixed site transmitters for use in epidemiological exposure assessment. The proposed model extends an existing model toward the prediction of indoor exposure, that is, at the homes of potential study