The paper investigates the in#uence of tolerating the shortage of energy supplies on the economy of cogeneration systems in consideration of energy demands as random variables. To make a reasonable investigation into the in#uence, an optimal unit sizing method proposed by the authors is adopted afte
Optimal unit sizing of fuel cell cogeneration systems in consideration of performance degradation
β Scribed by Koichi Ito; Satoshi Gamou; Ryohei Yokoyama
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 185 KB
- Volume
- 22
- Category
- Article
- ISSN
- 0363-907X
No coin nor oath required. For personal study only.
β¦ Synopsis
The influence of the life of a cell stack due to performance degradation on a system's economy is investigated in unit sizing of fuel cell cogeneration systems. An optimal unit sizing method proposed by the authors is extended to this case so that it enables the life and performance degradation of the cell stack to be considered. In the method, equipment capacities and maximum contract demands of utilities such as electricity and natural gas are determined so as to minimize the annual total cost leveled for a whole planning period based on the annualized costs method, in consideration of operational strategies which change with performance degradation of the cell stack. Numerical studies are carried out for normally and highly pressurized phosphoric acid fuel cell cogeneration systems installed in two urban areas. Through the studies, it is found that the life of the cell stack greatly influences system' economics and equipment capacities.
π SIMILAR VOLUMES
## Abstract In this paper, a parametric study of a combined proton exchange membrane (PEM) fuel cell and tripleβeffect absorption cooling system (TEACS) is undertaken to investigate the effect of different operating conditions and system parameters on the COPs, efficiency of the fuel cell and the i
## Abstract An investigation of preleached PtCo/C catalysts for the oxygen reduction reaction (ORR) was carried out at 75βΒ°C in sulphuric acid electrolyte by using a gasβfed halfβcell in order to evaluate their stability characteristics. The influence of different leaching methods on catalyst stabi
The breakdown of dissolved TCE in a two-step bioremediation system is described. In the first reactor, the organism Methylosinus trichosporium OB3b is grown; in the second reactor, consisting of three 17-L column reactors in series, the cells degrade TCE. A special design allowed both for the additi