𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Optimal speed as a function of system performance for continuous flow analyzers

✍ Scribed by Svetla Angelova; H.W. Holy


Publisher
Elsevier Science
Year
1983
Tongue
English
Weight
515 KB
Volume
145
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


The limitation to high rates of sample throughput with continuous flow automated analyzers is unacceptably high sample-to-sample carry-over. Previous programs for carryover correction have involved relatively large computer capacities. Here, the simple expression derived for carry-over can be easily programmed in BASIC for a Commodore PET operating in real time. The program includes peak picking and calculation of the calibration graph and sample concentrations. At 240 samples per hour, the results obtained for total protein (linear calibration graph) and haptoglobin (non-linear calibration plot) showed acceptable precision and recovery and correlated well with the same determination conducted at normal operating speeds. Standard AutoAnalyzer equipment was used throughout. A parameter which monitors the instrument function is also calculated; this replaces the conventional visual examination of the curve for function monitoring. At high sample rates with degraded curves, visual curve examination is not effective.


πŸ“œ SIMILAR VOLUMES


Coolant flow rate vs. agitator speed as
✍ H.R. Demo; O.A. Iglesias; I.H. Farina; E. Willis; M. De Santiago πŸ“‚ Article πŸ“… 1972 πŸ› Elsevier Science 🌐 English βš– 833 KB

The performance of a CSTR temperature feedback proportional control when coolant flow rate and agitator speed are being used as control variables, is analyzed. The reactor and jacket dynamics are included. The non-linear equations are integrated numerically and the state plane for each control varia

Peptide mapping of bovine pancreatic rib
✍ Theodore W. Thannhauser; Charles A. McWherter; Harold A. Scheraga πŸ“‚ Article πŸ“… 1985 πŸ› Elsevier Science 🌐 English βš– 754 KB

A procedure, developed for the cleavage and reversible blocking of disulfide bonds of proteins by S-sulfonation in preparation for peptide mapping, was applied to ribonuclease A. The complete peptide maps of sulforibonuclease A using limited Staphylococcus aureus protease digestion, tryptic digestio

The multi-step reactions for the synthes
✍ Sumeet K. Sharma; Ram S. Shukla; Parimal A. Parikh; Raksh V. Jasra πŸ“‚ Article πŸ“… 2009 πŸ› Elsevier Science 🌐 English βš– 313 KB

Kinetics of multi-step reactions including hydroformylation, aldol condensation and hydrogenation was carried out in a single pot for optimization of the reaction parameters for the synthesis of C 8 aldehydes and alcohol from propene using an eco-friendly multi-functional heterogeneous catalyst syst