𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Optimal pulse durations for the treatment of leg telangiectasias with a neodymium YAG laser

✍ Scribed by Eric C. Parlette; William F. Groff; Matthew J. Kinshella; Yacov Domankevitz; Jennifer O'Neill; E. Victor Ross


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
417 KB
Volume
38
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Background

Leg veins can be effectively treated with lasers. However, the optimal pulse duration for small leg veins has not been established in human studies with a Nd:YAG laser.

Objectives

The purpose of this study was to investigate a range of pulse durations to determine an optimal pulse duration for clearance of leg veins.

Study Design/Materials and Methods

After mapping and photo documentation of the leg veins to be treated, a variable pulse duration Neodymium:Yttrium Aluminum Garnet (Nd:YAG) laser (3–100 milliseconds) was used in a single test site session. Pulse durations of 3, 20, 40, 60, 80, and 100 milliseconds were used. At the 3‐week follow‐up, the optimal pulse duration was defined as that pulse duration which resulted in the most complete clearance of vessels with the least side effects. Up to 20 vessels were then treated using the established “optimal” pulse duration. Final evaluation was at 16 weeks after the initial visit. Three blinded observers rated the percent of vessels completely cleared based on initial and final photographs.

Results

Eighteen patients completed the study. Fluence thresholds for immediate vessel changes varied depending on spot size and vessel diameter, with larger fluences required for smaller spot sizes and smaller vessels. Shorter pulse durations (≤20 milliseconds) were associated with occasional spot sized purpura and spot sized post‐inflammatory hyperpigmentation. Longer pulse durations (40–60 milliseconds) achieved superior vessel elimination with less post‐inflammatory hyperpigmentation. With a single laser treatment, 71% of the treated vessels cleared.

Conclusions

Compared to shorter pulses (<20 milliseconds), longer pulses may provide gentler heating of the vessel and a greater ratio of contraction to thrombosis. Lasers Surg. Med. 38:98–105, 2006. © 2005 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Optimal pulse durations for the treatmen
✍ E.V. Ross; K.J. Meehan; S. Gilbert; Y. Domankevitz 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 197 KB 👁 1 views

## Abstract ## Background and Objectives Determine optimal settings using a long pulse 755 nm alexandrite laser in the treatment of superficial leg veins. ## Study Design\Materials and Methods Fifteen patients with Fitzpatrick skin types I–III with telangiectasia ranging from 0.2 to 1.0 mm were

Treatment of leg veins with the long pul
✍ Taro Kono; Takashi Yamaki; Ali Rıza Erçöçen; Osamu Fujiwara; Motohiro Nozaki 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 183 KB

## Abstract ## Background and Objectives Attempts at using the pulsed dye laser (PDL) operating at 585 nm wavelength and 0.45 milliseconds pulse duration to treat leg veins have been notably unsuccessful. The aim of this study is to evaluate the efficacy and complications of the 595 nm long PDL in

Comparative pilot study evaluating the t
✍ Charlotte M. Coles; Richard S. Werner; Brian D. Zelickson 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 181 KB 👁 1 views

## Abstract ## Background and Objective To date there have been very few side by side comparison studies of laser versus sclerotherapy in treating small leg veins. This study compares a long pulsed Nd:YAG laser with contact cooling to sclerotherapy for treating small diameter leg veins by evaluati

Long pulse Nd:YAG laser for treatment of
✍ Mario A. Trelles; I. Allones; M.J. Martín-Vázquez; O. Trelles; M. Vélez; S. Mord 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 240 KB 👁 1 views

## Abstract ## Background and Objectives This study assessed subjectively and objectively the efficacy of a long‐pulsed Nd:YAG laser system in clearing dermal leg veins, successful treatment of which remains problematic. ## Study Design/Patients and Methods Forty female patients (24–58 years old

Leg telangiectasia treatment with a 1.5
✍ Hohenleutner, Ulrich; Walther, Thomas; Wenig, Matthias; Bäumler, Wolfgang; Landt 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 126 KB 👁 1 views

## Background and Objective: Preliminary results indicate that pulsed dye lasers (PDL) with 1.5 ms pulsewidth and 595 nm wavelength are effective in the treatment of leg telangiectasia. The aim of this study was to evaluate if the clinical results could be improved by a) an effective skin cooling