Event-related BOLD fMRI data is modeled as a linear time-invariant system. Together with Bayesian inference techniques, a statistical test is developed for rigorously detecting linearity/nonlinearity in the BOLD response system. The test is applied to data collected from eight subjects using an even
Optimal experimental design for event-related fMRI
β Scribed by Anders M. Dale
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 133 KB
- Volume
- 8
- Category
- Article
- ISSN
- 1065-9471
No coin nor oath required. For personal study only.
β¦ Synopsis
An important challenge in the design and analysis of event-related or single-trial functional magnetic resonance imaging (fMRI) experiments is to optimize statistical efficiency, i.e., the accuracy with which the event-related hemodynamic response to different stimuli can be estimated for a given amount of imaging time. Several studies have suggested that using a fixed inter-stimulus-interval (ISI) of at least 15 sec results in optimal statistical efficiency or power and that using shorter ISIs results in a severe loss of power. In contrast, recent studies have demonstrated the feasibility of using ISIs as short as 500 ms while still maintaining considerable efficiency or power. Here, we attempt to resolve this apparent contradiction by a quantitative analysis of the relative efficiency afforded by different event-related experimental designs. This analysis shows that statistical efficiency falls off dramatically as the ISI gets sufficiently short, if the ISI is kept fixed for all trials. However, if the ISI is properly jittered or randomized from trial to trial, the efficiency improves monotonically with decreasing mean ISI. Importantly, the efficiency afforded by such variable ISI designs can be more than 10 times greater than that which can be achieved by fixed ISI designs. These results further demonstrate the feasibility of using identical experimental designs with fMRI and electro-/magnetoencephalography (EEG/MEG) without sacrificing statistical power or efficiency of either technique, thereby facilitating comparison and integration across imaging modalities.
π SIMILAR VOLUMES
Solid lipid nanoparticles (SLN) have been extensively investigated as a promising drug delivery system for controlling the release of therapeutic agents. Currently, there are many manufacturing methods available for SLN, including the high pressure homogenization method and the microemulsion techniq
## Abstract Acoustic noise from the imaging gradients presents a major difficulty in functional MRI (fMRI) studies of auditory cortical function. For studies involving hearingβimpaired pediatric subjects, the auditory stimuli should be presented during completely silent gradient intervals. In addit
## Abstract Taskβcorrelated motion artifacts that occur during functional magnetic resonance imaging can be mistaken for brain activity. In this work, a new selective detrending method for reduction of artifacts associated with taskβcorrelated motion (TCM) during speech in eventβrelated functional
An experimental arrangement is described that maximizes the dosimetric information that can be obtained during in vitro studies with ELF magnetic fields. The arrangement enables researchers to distinguish between a purely magnetic-field effect and one that also involves the electric fields and curre