## Abstract ## Purpose To evaluate the potential of a new lipophilic paramagnetic complex [Gd(Bz‐TTDA)]^2–^ [(4s)‐4‐benzyl‐3,6,10‐tri(carboxymethyl)‐3,6,10‐triazadodecandioic acid]^2–^ designed for use as a hepatobiliary MR contrast agent. ## Materials and Methods MR imaging studies for normal a
Optimal dose of hepatobiliary contrast agent for MR cholangiography: Experimental study in rats
✍ Scribed by Shinji Hirohashi; Rina Hirohashi; Hideo Uchida; Satoru Kitano; Megumi Akira; Wataru Ono; Hajime Ohishi; Naoki Kato; Masaya Takahashi; Tomoaki Miyazawa
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 648 KB
- Volume
- 8
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The purpose of this study is to clarify the optimal dose of gadolinium‐ethoxybenzyl‐diethylenetriaminepentaacetic acid (Gd‐EOB‐DTPA) for cholangiography in conventional T1‐weighted imaging. We divided 30 rats into three dose groups (3, 10, and 30 μmol/kg). For the in vitro study, we collected bile and measured the concentration of gadolinium in bile after Gd‐EOB‐DTPA injection. T1‐weighted images of the collected bile were obtained for measurement of signal intensity. For the in vivo study, we obtained T1‐weighted images before and after injection and evaluated bile duct/liver contrast by the signal intensity ratio and visual assessment of the images. The gadolinium concentration had an early peak; however, the signal intensity of the bile had a later peak because of the high gadolinium concentration during the early phase, which induced a T2‐shortening effect. Optimal bile duct/liver contrast was obtained in the 10‐μmol/kg groups at all time points. We conclude that the optimal dose of Gd‐EOB‐DTPA for MR cholangiography in rats is 10 μmol/kg, one‐third of the dose used in liver imaging.
📜 SIMILAR VOLUMES
With a recently described rat model technique for direct hepatic injection of tumor cells for imaging research, there were concerns that the injection itself might produce lesions detectable with magnetic resonance (MR) imaging, thereby producing false-positive results. To examine this possibility,
## Abstract ## Purpose To compare the differences between macromolecular and small molecular contrast agents in interstitial magnetic resonance (MR) lymphography. ## Materials and Methods In two groups of rabbits (__N__ = 12 each), 0.5‐mL volumes of 0.5 M and 0.1 M gadodiamide, respectively, wer
## Abstract ## Purpose To determine the diagnostic value of a new ultrasmall superparamagnetic iron oxide Clariscan®, (NC100150) for the evaluation of renal perfusion in an animal model using a 3D‐FFE‐EPI sequence. ## Materials and Methods Four groups of four rabbits each were imaged after bolus