## Abstract An optimal sampling schedule strategy based on the Fisher information matrix and the D‐optimality criterion has previously been proposed as a formal framework for optimizing inversion time scheduling for multi‐inversion‐time arterial spin labeling experiments. Optimal sampling schedule
Optimal design of pulsed arterial spin labeling MRI experiments
✍ Scribed by Jingyi Xie; Daniel Gallichan; Roger N. Gunn; Peter Jezzard
- Book ID
- 102955137
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 742 KB
- Volume
- 59
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Quantitative measurement of cerebral blood flow (CBF) using arterial spin labeling (ASL) MRI requires the acquisition of multiple inversion times (TIs) and the application of an appropriate kinetic model. The choice of these sampling times will have an impact on the precision of the estimated parameters. Here, optimal sampling schedule (OSS) design techniques, based on the Fisher Information approach, are applied in order to derive an optimal sampling scheme for pulsed arterial spin labeling (PASL) experiments. Such an approach should improve the precision of parameter estimation from experimental data, and provide a formal framework for optimally selecting a limited number of samples. In this study, we aimed to optimize the estimation precision of CBF and bolus arrival time from the PASL data. The performance of OSS was compared to a more standard evenly distributed sampling schedule (EDS) using both simulated and measured experimental data sets. It was found that OSS was able to significantly improve the precision of parameter estimation in PASL studies that sought to estimate either both CBF and bolus arrival time, or CBF alone. Magn Reson Med, 2008. © 2008 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
The purpose of this study was to establish a normal range for the arterial arrival time (AAT) in whole-brain pulsed arterial spin labeling (PASL) cerebral perfusion MRI. Healthy volunteers (N 5 36, range: 20 to 35 years) provided informed consent to participate in this study. AAT was assessed in mul
## Abstract A major difference between arterial‐spin‐labeling MRI and gold‐standard radiotracer blood flow methods is that the compartment localization of the labeled spins in the arterial‐spin‐labeling image is often ambiguous, which may affect the quantification of cerebral blood flow. In this st
## Abstract ## Purpose To investigate the feasibility and utility of arterial spin labeling (ASL) perfusion MRI for characterizing alterations of cerebral blood flow (CBF) in pediatric patients with arterial ischemic stroke (AIS). ## Materials and Methods Ten children with AIS were studied withi
## Abstract Imaging the contribution of different arterial vessels to the blood supply of the brain can potentially guide the treatment of vascular disease and other disorders. Previously available only with catheter angiography, vessel‐selective labeling of arteries has now been demonstrated with