𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Optical-thermal simulation of human tonsillar tissue irradiation: Clinical implications

✍ Scribed by Rahul K. Shah; Babak Nemati; Lihong V. Wang; Mark S. Volk; Stanley M. Shapshay


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
121 KB
Volume
27
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

✦ Synopsis


Background and objective:

Mucosa intact laser tonsillar ablation is an alternative to conventional tonsillectomy. the efficacy of this procedure was demonstrated in canines, but establishing the safety of irradiating human tonsils is paramount.

Study design/materials and methods:

An optical-thermal simulation of tonsillar tissue irradiation was previously developed, but the effect of varying parameters was not investigated. the tissue response to irradiation at 5-25 watts for 1 minute and 10 watts for 10 seconds to 162 seconds is simulated.

Results:

At 15 watts and greater, the peak temperature is over 100 degrees c and the mucosal temperature is over 70 degrees c. at the depth of the tonsil, the temperature does not vary significantly. the peak temperature is at 1 mm. the radial temperature profile is not significantly altered by longer irradiation times.

Conclusions:

The optimal dosimetry parameters for irradiation of human tonsillar tissue at 805 nm with the milta technique is under 15 watts for approximately 1 minute.