Optical resonator for high-power transverse flow CO2 lasers
β Scribed by I. Gutu; C. Petre; I. Ivanov; I.N. Mihailescu
- Publisher
- Elsevier Science
- Year
- 2003
- Tongue
- English
- Weight
- 973 KB
- Volume
- 35
- Category
- Article
- ISSN
- 0030-3992
No coin nor oath required. For personal study only.
π SIMILAR VOLUMES
For a high-power CO 2 laser with a close-confined structure, the compositions and ratios of gas mixtures are changed due to electron impacts during the laser-operating period. As a result, the laser performance is gradually degraded, even to non-lasing output. In this paper, three different methods
A laser power meter based on water as an absorbing medium has been developed to measure multi-kilowatt CO 2 laser power with high sensitivity and accuracy. Water absorbs CO 2 laser radiation readily within a very thin layer. Though water has large thermal capacity, due to short absorption length, it