Operational experience of once through MSF desalination units
โ Scribed by AliAbdullah Al Owais; R.K. Nijhawan; P.K. Budhiraja
- Publisher
- Elsevier Science
- Year
- 1989
- Tongue
- English
- Weight
- 1005 KB
- Volume
- 73
- Category
- Article
- ISSN
- 0011-9164
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
A MSF desalination plant was provided as an auxiliary unit at Abu-Kammash Chemical Complex to meet the demand of process water and domestic water supply of the town. The plant with a nominal capacity of 100 m3/h, has 29 stages i24 heat recovery stages, 4 heat rejection stages and 1 degassing stage)
The paper presents a study of the effect of fouling, due to scale formation, of preheater tubes on the thermal performance of once through multi stage desalination plant . The mathematical model developed was used to find, the decrease in the plant performance ratio, and the increase of the ratio of