On the scope and interpretation of the Tofts models for DCE-MRI

โœ Scribed by Steven P. Sourbron; David L. Buckley


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
368 KB
Volume
66
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

The Tofts model (TM) and extended Tofts model (ETM) have become a standard for the analysis of dynamic contrastโ€enhanced MRI. In this study, a mathematical analysis is used to identify exactly in which tissue types the Tofts models may be applied. The results show that the TM is accurate if and only if the tissue is weakly vascularised (small blood volume). The ETM is additionally accurate in highly perfused tissues (high blood flow). In tissues that are highly vascularised, or where tracer exchange is very fast or very slow, TM and ETM accurately fit the data but lead to a misinterpretation of the parameters. In tissue types with intermediate vascularity, perfusion and tracer exchange, neither model offers a good fit to the tissue concentrations. A good fit can be obtained with a measured input function by reducing the temporal resolution, but this does not improve the accuracy of the parameters. In conclusion, the Tofts models only produce reliable parameter values if the tissue is weakly vascularized (TM or ETM) or highly perfused (ETM). Without prior knowledge that at least one of these constraints is fulfilled, the physiological interpretation of the values produced by the Tofts models is unclear. Magn Reson Med, 2011. ยฉ 2011 Wileyโ€Liss, Inc.


๐Ÿ“œ SIMILAR VOLUMES


Temporal resolution and SNR requirements
โœ Lucy E. Kershaw; Hai-Ling Margaret Cheng ๐Ÿ“‚ Article ๐Ÿ“… 2010 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 621 KB

## Abstract Dynamic contrastโ€enhanced MRI has been used in conjunction with tracer kinetics modeling in a wide range of tissues for treatment monitoring, oncology drug development, and investigation of disease processes. Accurate measurement of model parameters relies on acquiring data with high te

Comparative study into the robustness of
โœ Caleb Roberts; Basma Issa; Andrew Stone; Alan Jackson; John C. Waterton; Geoffre ๐Ÿ“‚ Article ๐Ÿ“… 2006 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 317 KB

## Abstract ## Purpose To evaluate and compare the reproducibility of the preferred phenomenological parameter IAUC~60~ (initial area under the timeโ€concentration curve [IAUC] defined over the first 60 seconds postenhancement) with the preferred modeling parameter (__K__^trans^), as derived using

k-Space interpretation of the Rose Model
โœ Richard Watts; Yi Wang ๐Ÿ“‚ Article ๐Ÿ“… 2002 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 723 KB

Noise limitation on the detected spatial resolution, described by the Rose Model, is well known in X-ray imaging and routinely used in designing X-ray imaging protocols. The purpose of this article is to revisit the Rose Model in the context of MRI where image data are acquired in the spatial freque