๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

On-line high-performance liquid chromatographic- electrospray ionization mass spectrometric method for the study of tamoxifen metabolism

โœ Scribed by R.M. Jones; Z.-X. Yuan; J.H. Lamb; C.K. Lim


Publisher
Elsevier Science
Year
1996
Tongue
English
Weight
576 KB
Volume
722
Category
Article
ISSN
1873-3778

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


High-performance Liquid Chromatographic/
โœ M. A. M. Nawwar; M. S. Marzouk; W. Nigge; M. Linscheid ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 592 KB

A screening method based on high-performance liquid chromatography (HPLC) interfaced to electrospray ionization mass spectrometry (ESI-MS) with detection of negative ions was devised and the conditions for assaying the complex mixture of gallotannins, ellagitannins and ร‘avonoids of aqueous ethanolic

Simple, sensitive and rapid liquid chrom
โœ N. V. S. Ramakrishna; K. N. Vishwottam; S. Puran; S. Manoj; M. Santosh; M. Kotes ๐Ÿ“‚ Article ๐Ÿ“… 2004 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 159 KB ๐Ÿ‘ 1 views

## Abstract A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simp

Phenyl ring structures as stationary pha
โœ S. R. Needham; P. R. Brown; K. Duff ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 85 KB ๐Ÿ‘ 2 views

To produce a large mass spectral signal in the analysis of basic drugs by high performance liquid chromatography/electrospray ionization mass spectrometry (HPLC/ESI-MS), a high percentage of organic solvent is needed in the mobile phase. With the commonly used reversed phase columns (C18, C8 and C4)

A new high-performance liquid chromatogr
โœ Laura Sabatini; Anna Barbieri; Marco Tosi; Francesco Saverio Violante ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 137 KB

## Abstract A new highโ€performance liquid chromatographic/electrospray ionization tandem mass spectrometric (HPLC/ESIโ€MS/MS) method was developed for the simultaneous quantification of 5โ€fluorouracil (5FU), methotrexate (MTX) and cyclophosphamide (CP) in environmental samples. These compounds, comm

Development and validation of a liquid c
โœ Ariadni Vonaparti; Michael Kazanis; Irene Panderi ๐Ÿ“‚ Article ๐Ÿ“… 2006 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 338 KB ๐Ÿ‘ 1 views

## Abstract A new method was developed and fully validated for the quantitation of benazepril, benazeprilat and hydrochlorothiazide in human plasma. Sample pretreatment was achieved by solidโ€phase extraction (SPE) using Oasis HLB cartridges. The extracts were analysed by highโ€performance liquid chr