On-line determination of vanadium by adsorptive stripping voltammetry
β Scribed by Gillian M. Greenway; Georg Wolfbauer
- Publisher
- Elsevier Science
- Year
- 1995
- Tongue
- English
- Weight
- 964 KB
- Volume
- 312
- Category
- Article
- ISSN
- 0003-2670
No coin nor oath required. For personal study only.
β¦ Synopsis
An on-line electrochemical stripping procedure for trace determination of vanadium was developed combining the advantages of adsorptive stripping voltammetry with flow injection analysis. The vanadium formed a complex with eupferron in an acetate buffered solution which adsorbed onto the mercury film electrode. An amplification of the stripping current was attained by the catalytic reduction of the adsorbed complex in the presence of bromate. The complex was d 9 sited at + 200 mV (vs. Ag/AgCl) then stripped using a differential pulse waveform with a scan rate of 10 mV s-', the re uction peak occurring at + 100 mV. Under optimized conditions a limit of detection of 8 ng I-' and mid-range standard deviation of 2-3% were obtained. The response was linear up to 3.5 pg 1-l with a sensitivity of 0.1 mA 1 pg-'. Sample matrixes containing high salt concentrations had to be measured by anodic stripping, depositing the complex cathodically at 0.0 V and resuming with a scan to + 150 mV to prevent calomel formation.
π SIMILAR VOLUMES
A voltammetrlc method for the determmation of uranium m natural waters m the concentratlon range from 0.4 pg 1-l to 0.2 mg 1.' is described. The method IS based on adsorptlve accumulation of the uranium(VI)-pyrocatechol complex on the hanging mercury drop electrode followed by the reduction of the a
## Abstract A method for the voltammetric determination of vanadium using a carbon paste electrode (CPE) was described. The new procedure is based on the adsorptive accumulation of the V(V)βalizarin red S(ARS) complex onto the surface of the CPE, followed by the electrochemical reduction of adsorbe
## Ultratrace concentrations of uranium(V1) have been determined using adsorptive stripping voltammetry of the uranium-chloranilic acid complex (2,5-dichloro-3,6-dihydroxy-1,4-benzoquinone). The detection limit was calculated to 24 rig/l.. The most significant advantage of the method described is
## Abstract A sensitive and selective onβline voltammetric procedure for determination of traces of labile chromium is presented. The pulsed potential accumulation was proposed for the minimization of interferences of surface active substances and foreign ions. The calibration plot was linear from