𝔖 Bobbio Scriptorium
✦   LIBER   ✦

On-line coated columns for the spectrophotometric determination of metals by continuous flow analysis

✍ Scribed by Yuri A. Zolotov; Irina M. Maksimova; Elena I. Morosanova; Andrei A. Velikorodny


Publisher
Elsevier Science
Year
1995
Tongue
English
Weight
625 KB
Volume
308
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


The immobilization of xylenol orange, 1-(2'-pyridylazo)-2-naphthol and ( p-sulfophenylazo)-2'-sulfo-4'-nitrodiazoaminobenzene disodium salt (Cadion) on reversed-phase silica CC,,, C,, phenyl, C,, C=N) and capillary tubes with a hydrophobic inner surface (C,, C-phenyl, C,) in the flow were studied. The flow system including a microcolumn or a capillary tube for the determination of metal ions is suggested. Its versatility and flexibility is provided by on-line coating of the sorbents or inner surface of the capillary tubes. The procedures for the flow spectrophotometric determination of Cd, Co, Cu and Fe(III) in the range 8 X lOma-X 10e5 M with on-line preconcentration are suggested. The preconcentration factors are up to 9 for the microcolumns and up to 19 for the capillary tubes. The throughput of the system is 19 samples per hour. The method of simultaneous determination of two metals in the mixture (Cu(II) and Co(II), Co(H) and Fe(III), Fe(II1) and Zn, Mn(I1) and Pb(I1)) in the range 1 X 10K-7 X lo-' M at 30-60 samples per hour is developed.


πŸ“œ SIMILAR VOLUMES


Determination of Vanadium by Its Catalyt
✍ Ali A. Ensafi; A. Kazemzadeh πŸ“‚ Article πŸ“… 1996 πŸ› Elsevier Science 🌐 English βš– 132 KB

The use of a gallocyanine-bromate oxidation system for the direct determination of vanadium (0.020-100 ng/ml) with spectrophotometric detection is described. The decrease in absorbance results from the oxidation of gallocyanine by bromate in the presence of vanadium as a catalyst. The effects of imp

Chemically coupled spectrophotometric as
✍ Lawrence C. Davis; Gary A. Radke πŸ“‚ Article πŸ“… 1984 πŸ› Elsevier Science 🌐 English βš– 702 KB

Micromethods of direct chemical coupling have been developed for several different enzyme reactions, using the principles of flow injection analysis. Samples of l-25 ~1 are injected into a flowing stream of color-forming reagents and the peak of color change is measured after about 1 min. Alternativ

On-line trace enrichment for the determi
✍ Pilar CampΓ­ns-FalcΓ³; Rosa HerrΓ‘ez-HernΓ‘ndez; Adela Sevillano-Cabeza πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 437 KB

A chromatographic method based on liquid chromatography (LCJ using column-switching for the determination of ethacrynic acid in urine samples, is described. The proposed system uses an Hypersil ODS-Cl& 30 pm (20 mm x 2.1 mm i.d.) pre-column for the pre-concentration and separation of ethacrynic acid