This paper treats the theoretical fatigue analysis of non-Gaussian random loadings. It first reviews a method recently developed by the Authors, which is capable to account for the effect of load bandwidth and non-normality. Fatigue lives from simulated Gaussian and non-Gaussian loadings, as well as
On fatigue damage assessment in bimodal random processes
β Scribed by D. Benasciutti; R. Tovo
- Publisher
- Elsevier Science
- Year
- 2007
- Tongue
- English
- Weight
- 394 KB
- Volume
- 29
- Category
- Article
- ISSN
- 0142-1123
No coin nor oath required. For personal study only.
β¦ Synopsis
Rainflow fatigue damage in bimodal Gaussian processes is discussed. Some methods specifically developed for bimodal processes (e.g., single-moment, Jiao-Moan, Sakai-Okamura and Fu-Cebon method) are compared with the Tovo-Benasciutti method, a new approach valid for the broader class of wide-band processes. Further, an improvement of the Fu-Cebon method is also proposed. Numerically simulated bimodal random processes are used to compare the accuracies of all methods and to find the optimal range for their applicability. The single-moment, the modified Fu-Cebon and the Tovo-Benasciutti methods are seen as the most accurate over a wide combination of bimodal spectra.
π SIMILAR VOLUMES
The paper presents an experimental approach for the analysis of localized fatigue damage processes during fatigue testing of welded steel structures by thermographic investigations of thermomechanical coupling phenomena. Special data processing of the recorded infrared sequences is proposed to separ
## Abstract In this paper generalized criteria of multiaxial random fatigue based on stress, strain and strain energy density parameters in the critical plane have been discussed. The proposed criteria reduce multiaxial state of stress to the equivalent uniaxial tensionβcompression or alternating b
This study demonstrates that an in-situ nondestructive, ultrasonic surface wave technique can successfully detect the onset and extent of matrix cracking fati~c damage in a titanium metal matrix composite (MMC). A quasi-isotropic [0/\_+45/90]s SCS-6/Timetal 21S MMC material was used for room tempera