The effect of off-resonance irradiation on the water proton NMR signal intensity has been investigated as follows: (a) in the presence of a paramagnetic probe like manganese(II); (b) in the presence of bovine serum albumin (BSA) and two gadolinium(III) complexes, Gd-DTPA and Gd-BOPTA; (c) in the pre
Off-resonance frequency filtered magnetic resonance imaging
✍ Scribed by Jure Medič; Sašo Tomažič
- Book ID
- 104060378
- Publisher
- Elsevier Science
- Year
- 2010
- Tongue
- English
- Weight
- 788 KB
- Volume
- 28
- Category
- Article
- ISSN
- 0730-725X
No coin nor oath required. For personal study only.
✦ Synopsis
One of the main problems with rapid magnetic resonance imaging (MRI) techniques is the artifacts that result from off-resonance effects. The proposed off-resonance frequency filtered MRI (OFF-MRI) method focuses on the elimination of off-resonance components from the image of the observed object. To maintain imaging speed and simultaneously achieve good frequency selectivity, MRI is divided into two steps: signal acquisition and post-processing. After the preliminary phase in which we determine imaging parameters, MRI takes place; the signal from the same object is successively acquired M times. As a result, we obtain M partial signals in k-space, from which we form the image of the observed object in the post-processing phase, after signal acquisition has been completed. This paper demonstrates that with proper selection of acquisition parameters and weighting coefficients in the post-processing phase, OFF-MRI is equivalent to filtering the signal by finite impulse response filter of length M. It is shown that with M successive acquisitions M-1 off-resonance components can be eliminated (filtered-out) from images, and therefore, only two acquisitions are needed to eliminate one off-resonance components. On the other hand, with OFF-MRI, it is also possible to form the image of an arbitrary off-resonance component by eliminating all other off-resonance components, including the on-resonance component. The proposed OFF-MRI method is suitable for MRI where rapid acquisition is required and elimination of off-resonance components can improve reliability of measurements.
📜 SIMILAR VOLUMES
## Abstract When constructing MR images from acquired spatial frequency data, it can be beneficial to apply a low‐pass filter to remove high frequency noise from the resulting images. This amounts to attenuating high spatial frequency fluctuations that can affect detected MR signal. A study is pres