The biocompatibility of a viscous poly(ortho ester) (POE) intended for prolonged intraocular drug delivery was studied. This hydrophobic and bioerodable carrier was subconjunctivally injected in rabbits and evaluated both clinically and histologically. To assess the cause of the triggered transient
Ocular biocompatibility of a poly(ortho ester) characterized by autocatalyzed degradation
✍ Scribed by Einmahl, Suzanne ;Ponsart, St�phanie ;Bejjani, Riad A. ;D'Hermies, Fran�ois ;Savoldelli, Michelle ;Heller, Jorge ;Tabatabay, Cyrus ;Gurny, Robert ;Behar-Cohen, Francine
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 413 KB
- Volume
- 67A
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The biocompatibility of autocatalyzed poly(ortho ester) (POE~70~LA~30~), a viscous, hydrophobic, bioerodible polymer, was investigated. POE~70~LA~30~ was synthesized, sterilized by gamma irradiation, and injected in rabbit eyes at adequate volumes through subconjunctival, intracameral, intravitreal, and suprachoroidal routes. Clinical examinations were performed postoperatively at regular time points for 6 mo, and histopathologic analysis was carried out to confirm tissular biocompatibility. After subconjunctival injection, the polymer was well tolerated and persisted in the subconjunctival space for about 5 weeks. In the case of intracameral injections, polymer biocompatibility was good; the POE~70~LA~30~ bubble was still present in the anterior chamber for up to 6 mo after injection. No major histopathologic anomalies were detected, with the exception of a localized Descemet membrane thickening. After intravitreal administration, POE~70~LA~30~ biocompatibility was excellent, and no inflammatory reaction could be detected during the observation period. The polymer was degraded in approximately 3 mo. Suprachoroidal injections of POE~70~LA~30~ were reproducible and well tolerated. POE~70~LA~30~ triggered a slight elevation of the retina and choroid upon clinical observation. The polymer was detectable in the suprachoroidal space for about 6 mo. No inflammatory reaction and no major retinal anomalies could be detected by histology. In conclusion, POE~70~LA~30~ appears to be a promising biomaterial for intraocular application, potentially providing sustained drug delivery over an extended period of time, with a good tolerance. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 44–53, 2003
📜 SIMILAR VOLUMES
## Abstract Aliphatic segmented poly(ester amide)s, comprising a crystallizable amide phase and a flexible amorphous ester phase, were investigated for potential use in biomedical applications. By varying the amide content and the type of crystallizable amide segments, the polymer's thermal and mec
## Abstract This study aims to fundamentally understand the polymer network formed by poly(ethylene glycol) diacrylate (PEGDA) MW 700 and 3‐methoxypropylamine (3MOPA) as well as to characterize the degradation response of this material with and without applied cyclic stress. Macromer reaction chemi
The hydrolytic degradation of technical poly(ethylene terephthalate) (PET) was investigated by means of different methods such as size-exclusion chromatography (SEC), viscometry, light-scattering, thin-layer chromatography, end-group titration, and matrix-assisted laser desorption/ionization mass sp