๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Occlusion of a Giant Saphenous Vein Graft Aneurysm Using Distal Coil Embolisation and a Proximal Vascular Plug

โœ Scribed by R.I. Hatrick; M.W.I. Webster; C.J. Occleshaw; P.F. Milsom


Book ID
119255249
Publisher
Elsevier Science
Year
2008
Tongue
English
Weight
596 KB
Volume
17
Category
Article
ISSN
1443-9506

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Treatment of a ruptured saphenous vein g
โœ Adriano R. Tonelli; Aashish K. Desai; R. David Anderson ๐Ÿ“‚ Article ๐Ÿ“… 2008 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 153 KB

## Abstract Saphenous vein graft pseudoaneurysm is an uncommon complication of coronary bypass grafting. Hemoptysis associated with diffuse bleeding into the lung tissue may be the initial manifestation of this condition. We report a case of a saphenous vein graft pseudoaneurysm that presented with