𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Observation of stable crack growth in Al2O3 ceramics using a scanning acoustic microscope

✍ Scribed by A. Quinten; W. Arnold


Publisher
Elsevier Science
Year
1989
Tongue
English
Weight
800 KB
Volume
122
Category
Article
ISSN
0921-5093

No coin nor oath required. For personal study only.

✦ Synopsis


We employed ultrasonic techniques in order to gain information on the R-curve behavior of Al_,O~ ceramics. A reduction in the sound velocity has been observed at the crack tip of subcritically grown cracks. The measurements were carried out by time-of-flight measurements, and by evaluating the V(z) curves obtained from a scanning acoustic microscope. Furthermore, we could also observe effects related to the interaction of serrated crack walls by in situ experiments in the scanning acoustic microscope.

*Our samples were manufactured by Feldmtihle AG, Plochingen, F.R.G., (B40) and at the University of Dortmund (Dr. R. Steinbrech, N28). They have been characterized by K. B~ir, G. Kleist and T. Lexen, Kernforschungsanlage Jiilich (unpublished).


πŸ“œ SIMILAR VOLUMES


In-vivo observation of cells with a comb
✍ Selma Schenkl; Eike C. Weiss; Frank Stracke; Daniel Sauer; Martin Stark; Iris Ri πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 311 KB

## Abstract We present a combined multiphoton–acoustic microscope giving collocated access to the local morphological as well as mechanical properties of living cells. Both methods relay on intrinsic contrast mechanisms and dispense with the need of staining. In the acoustic part of the microscope,

Fracture resistance evaluation of RuO2-b
✍ Niko Sebastian Dorsch; Ilya Peshekhodov; Philipp Spies; Gerold A. Schneider πŸ“‚ Article πŸ“… 2008 πŸ› Elsevier Science 🌐 English βš– 663 KB