𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Numerical optimization of sequential cryogen spray cooling and laser irradiation for improved therapy of port wine stain

✍ Scribed by Matija Milanič; Wangcun Jia; J Stuart Nelson; Boris Majaron


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
742 KB
Volume
43
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

✦ Synopsis


Background and Objective: Despite application of cryogen spray (CS) precooling, customary treatment of port wine stain (PWS) birthmarks with a single laser pulse does not result in complete lesion blanching for a majority of patients. One obvious reason is nonselective absorption by epidermal melanin, which limits the maximal safe radiant exposure. Another possible reason for treatment failure is screening of laser light within large PWS vessels, which prevents uniform heating of the entire vessel lumen. Our aim is to identify the parameters of sequential CS cooling and laser irradiation that will allow optimal photocoagulation of various PWS blood vessels with minimal risk of epidermal thermal damage. Study Design and Methods: Light and heat transport in laser treatment of PWS are simulated using a custom 3D Monte Carlo model and 2D finite element method, respectively. Protein denaturation in blood and skin are calculated using the Arrhenius kinetic model with tissue-specific coefficients. Simulated PWS vessels with diameters of 30-150 mm are located at depths of 200-600 mm, and shading by nearby vessels is accounted for according to PWS histology data from the literature. For moderately pigmented and dark skin phototypes, PWS blood vessel coagulation and epidermal thermal damage are assessed for various parameters of sequential CS cooling and 532-nm laser irradiation, i.e. the number of pulses in a sequence (1-5), repetition rate (7-30 Hz), and radiant exposure. Results: Simulations of PWS treatment in darker skin phototypes indicate specific cooling/irradiation sequences that provide significantly higher efficacy and safety as compared to the customary single-pulse approach across a wide range of PWS blood vessel diameters and depths. The optimal sequences involve three to five laser pulses at repetition rates of 10-15 Hz. Conclusions: Application of the identified cooling/irradiation sequences may offer improved therapeutic outcome for patients with resistant PWS, especially in darker skin phototypes.


📜 SIMILAR VOLUMES


Cryogen spray cooling efficiency: Improv
✍ Guillermo Aguilar; Sergio H. Díaz; Enrique J. Lavernia; J. Stuart Nelson 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 156 KB 👁 1 views

## Abstract ## Background and Objectives Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser treatment of port wine stain (PWS) birthmarks. Unfortunately, CSC may not provide the necessary protection for patients with high concentrations of epidermal melanin.

Optimal cryogen spray cooling parameters
✍ Wim Verkruysse; Boris Majaron; B. Samuel Tanenbaum; J. Stuart Nelson 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 141 KB 👁 2 views

## Background and Objective: In dermatologic laser therapy, cryogen spray cooling (CSC) is a means to protect the epidermis while leaving dermal structures susceptible to thermal damage. The purpose of this study was to determine optimal spurt duration, s , and optimal delay, d , between the cryog

Improvement of port wine stain laser the
✍ Wangcun Jia; Guillermo Aguilar; Wim Verkruysse; Walfre Franco; J. Stuart Nelson 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 571 KB

## Abstract ## Background and Objectives Although cryogen spray cooling (CSC) in conjunction with laser therapy has become the clinical standard for treatment of port wine stain (PWS) birthmarks, the current approach does not produce complete lesion blanching in the vast majority of patients. The