Numerical and experimental investigation of heat transfer on heating surface during subcooled boiling flow of liquid nitrogen
β Scribed by Xiangdong Li; Wei Wei; Rongshun Wang; Yumei Shi
- Publisher
- Elsevier Science
- Year
- 2009
- Tongue
- English
- Weight
- 414 KB
- Volume
- 52
- Category
- Article
- ISSN
- 0017-9310
No coin nor oath required. For personal study only.
β¦ Synopsis
The active site density The bubble waiting time a b s t r a c t Closure correlations describing bubble nucleation and departure on the heating surface is indispensable when modeling subcooled boiling flow using a two-fluid model. Due to the small contact angle and surface tension, nucleation and departure of nitrogen vapor bubble has different characteristics to those of high-boiling liquids. For the purpose of accurate two-fluid model formulation, these factors have to be taken into consideration. In this study, some closure correlations of the bubble departure diameter, active site density and bubble waiting time were tested in the frame of the two-fluid model and the CFX code. Benchmark experiments were then performed to evaluate the correlations. Comparison of the numerical results against the experimental data demonstrates that the surface tension is crucial to modeling the bubble departure diameter and the active site density. The bubble waiting time correlation formulated according to bubble growth is expected to be used as a criterion of judging the transition from subcooled to saturated boiling.
π SIMILAR VOLUMES
## Abstract In this paper the effects of surface energy and surface roughness on the deposition of calcium sulphate during convective and subcooled flow boiling heat transfer to aqueous CaSO~4~ solutions are studied. The surfaces of several test heaters have been treated by Ion Beam Implantation, U
Subcooled flow film boiling experiments were conducted on a vertical flat plate, 30.5 cm in height, and 3.175 cm wide with forced convective upflow of subcooled water at atmospheric pressure. Data have been obtained for mass fluxes ranging from 0 to 700 kg/m 2 s, inlet subcoolings ranging from 0 to
In Eqs. ( 14) and ( 16) of the above article, one item depicting the inlet subcooling of the liquid nitrogen was inadvertently missing when the manuscript was prepared. This item is formulated as