๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Nuclear medicine in the diagnosis of cardiac contusion

โœ Scribed by Vincent Lopez-Majano; Pratiba Sansi; Robert Colter


Publisher
Springer
Year
1985
Tongue
English
Weight
486 KB
Volume
11
Category
Article
ISSN
0340-6997

No coin nor oath required. For personal study only.

โœฆ Synopsis


In 16 patients with blunt trauma to the chest, the role of cardiovascular nuclear medicine was evaluated using anterior chest flow assessment, with first-pass ejection fraction of left and right ventricles and 99mTc-pyrophosphate scintigraphy. The radiopharmaceutical used was pyrophosphate, labelled with approximately 20 mCi 99mTc. The anterior chest flow and first-pass ejection fractions were initially obtained during the injection of 99mTc-pyrophosphate and were followed up 3 h later by anterior, LAO 45 degrees, and left lateral views of the chest, using an LFOV gamma camera with a data processor. The results were compared with serial cardiac enzymes studies, electrocardiograms and echocardiograms. Of the patients, 77% showed scintigraphic evidence of cardiac contusion. The intensity of activity varied from grades I to II; five patients had abnormal echocardiographic findings. Only two had abnormal ejection fractions, and one patient had evidence of left ventricular aneurysm along with poor ventricular performance. Cardiac enzymes were found to be the least helpful. Electrocardiograms, though non-specific for myocardial damage, were abnormal in 62% of the patients. Eleven of our patients had both abnormal ECG and increased PYP uptake. Even though there is no agreement as to which noninvasive parameter is more sensitive in the diagnosis of myocardial contusion, 99mTc-pyrophosphate scintigraphy, in conjunction with ECG, seems promising in this respect.


๐Ÿ“œ SIMILAR VOLUMES


The use of gated radionuclide angiograph
โœ James E Fenner; Robert Knopp; Bradford Lee; Paul A dos Santos; Ralph J Wessel; C ๐Ÿ“‚ Article ๐Ÿ“… 1984 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 679 KB

No currently used diagnostic test is an accurate predictor of patients who will develop morbidity or mortality from cardiac contusion. In a prospective study we used gated cardiac radionuclide angiography to assess cardiac function in 30 patients with blunt chest trauma, and we compared the results

Cardiac nuclear medicine: Positron emiss
โœ Axel Storch-Becker; Klaus P. Kaiser; Ludwig E. Feinendegen ๐Ÿ“‚ Article ๐Ÿ“… 1988 ๐Ÿ› Springer ๐ŸŒ English โš– 630 KB

Positron-emission tomography (PET) and radioactively labelled substrates permit metabolic studies to be carried out in vivo and in situ with few if any limitations regarding the choice of substrates as long as they can be tagged with positron-emitting radionuclides, especially those like 11C and 13N