β¦ Synopsis
Abstract
The NMR peak integral is ideally linearly dependent on the sine of excitation angle (ΞΈ), which has provided unsurpassed flexibility in quantitative NMR by allowing the use of a signal of any concentration as the internal concentration reference. Controlling the excitation angle is particularly critical for solvent proton concentration referencing to minimize the negative impact of radiation damping, and to reduce the risk of receiver gain compression. In practice, due to the influence of RF inhomogeneity for any given probe, the observed peak integral is not exactly proportional to sin ΞΈ. To evaluate the impact quantitatively, we introduce a RF inhomogeneity factor I(ΞΈ) as a function of the nominal pulse excitation angle and propose a simple calibration procedure. Alternatively, I(ΞΈ) can be calculated from the probe's RF profile, which can be readily obtained as a gradient image of an aqueous sample. Our results show that without consideration of I(ΞΈ), even for a probe with good RF homogeneity, up to 5% error can be introduced due to different excitation pulse angles used for the analyte and the reference. Hence, a simple calibration of I(ΞΈ) can eliminate such errors and allow an accurate description of the observed NMR signal's dependence on the excitation angle in quantitative analysis. Copyright Β© 2011 John Wiley & Sons, Ltd.
π SIMILAR VOLUMES
Practical heteronuclear dipolar recoupling performances under magic angle spinning for SFAM and REDOR have been investigated under well-defined rf inhomogeneity environments with variation of resonance offsets for the irradiated nucleus. The heteronuclear dipolar recoupling efficiencies were quantit
## Abstract In this report we describe the three factors that need to be measured when quantitating an edited resonance relative to an internal standard using a surface coil. These factors are necessary by virtue of the water, fat suppressing, and localization schemes used in studying a ^1^H metabo
## Abstract ## Purpose To demonstrate the effects of inherent RF inhomogeneity on ramped RF excitation at 3.0T, and to introduce a simple correction for improving visualization of distal intracranial arteries in threeβdimensional timeβofβflight MR angiography (3DβTOFβMRA). ## Materials and Method