๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

New technique for capillary electrophoresis directly coupled with end-column electrochemiluminescence detection

โœ Scribed by Weidong Cao; Jifeng Liu; Xiurong Yang; Erkang Wang


Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
157 KB
Volume
23
Category
Article
ISSN
0173-0835

No coin nor oath required. For personal study only.

โœฆ Synopsis


A new end-column electrochemiluminescence (ECL) detection technique coupling to capillary electrophoresis (CE) is characterized. A 300 microm diameter Pt working electrode was used to directly couple with a 75 microm inner diameter separation capillary without an electric field decoupler. The hydrodynamic cyclic voltammogram (CV) of Ru(bpy) 3 2+ showed that electrophoretic current did not affect the ECL reaction. The presence of high-voltage (HV) field only resulted in the shift of the ECL detection potential. The distance of capillary to electrode was an important parameter for optimizing detection performance as it determined the characteristics of mass transport toward the electrode and the actual concentration of Ru(bpy) 3 2+ in the detection region. The optimum distance of capillary to electrode was decided by the inner diameter of the capillary, too. For a 75 microm capillary, the working electrode should be placed away from the capillary outlet at a distance within the range of 220-260 microm. The effects of pH value of ECL solution and molecular structure of analytes on peak height and theoretical plate numbers were discussed. Using the 75 microm capillary, under the optimum conditions, the method provided a linear range for tripropylamine (TPA) between 1 x 10(-10) and 1 x 10(-5) mol/L with correlation coefficient of 0.998. The detection limit (signal-to-noise ratio S/N = 3) was 5.0 x 10(-11) mol/L. The relative standard deviation in peak height for eight consecutive injections was 5.6%. By this new technique lidocaine spiked in a urine sample was determined. The method exhibited the linear range for lidocaine from 5.0 x 10(-8) to 1.0 x 10(-5) mol/L with correlation efficient of 0.998. The limit of detection (S/N = 3) was 2.0 x 10(-8) mol/L.


๐Ÿ“œ SIMILAR VOLUMES


Simultaneous Determination of Tramadol a
โœ Weidong Cao; Jifeng Liu; Haibo Qiu; Xiurong Yang; Erkang Wang ๐Ÿ“‚ Article ๐Ÿ“… 2002 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 136 KB ๐Ÿ‘ 2 views

Tramadol and lidocaine, used as analgesic and local anesthetic in surgery, are partly excreted by kidney. For the first time, we developed a simple and sensitive method, based on capillary electrophoresis with electrochemiluminescence (ECL) detection by end column mode without joint to monitor trama

End-Column Electrochemical Detection for
โœ Xiaojing Huang; Tianyan You; Tao Li; Xiurong Yang; Erkang Wang ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 119 KB ๐Ÿ‘ 2 views

Electrochemical detection of ยฎve species of aromatic amines at a carbon ยฎber microdisk electrode after separation by capillary electrophoresis is described. Under the optimum conditions, the detection limit for 3,4-dihydroxybenzylamine, N,N-dimethylaniline, p-phenylenediamine, p-aminophenol and anil