Neuro MR: Protocols
✍ Scribed by David J. Mikulis; Timothy P.L. Roberts
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 932 KB
- Volume
- 26
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Clinical MRI depends on a symbiosis between MR physics and clinical requirements. The imaging solutions are based on a balance between the “palette” of available image contrasts derived from nuclear spin physics and tissue biophysics, and clinical determinants such as the anticipated pathology and efficient use of imaging time. Imaging is therefore optimized to maximize diagnostic sensitivity and specificity through the development of protocols organized along the lines of major disease categories. In the other part of this two‐part review, the primary determinants of image contrast, including T1, T2, and T2*, were highlighted. The development of pulse sequences designed to optimize each of these image contrasts was discussed and the impact of technological innovation (parallel imaging and high‐field systems) on the manner in which these sequences could be modified to improve clinical efficacy was further emphasized. The scope of that discussion was broadened to include the application of: 1) water diffusion imaging used primarily for detection of pathologies that restrict the free movement of water in the tissues and for defining fiber tracts in the brain; 2) the intravenous administration of exogenous contrast agents (gadolinium‐diethylene triamine pentaacetic acid [GdDTPA]) for assessment of blood‐brain‐barrier (BBB) defects and brain blood flow; and 3) MR spectroscopy (MRS) for assessment of brain metabolites. The goal of this part is to discuss how these acquisitions are combined into specific protocols that can effectively detect and characterize, or in keeping with our artistic analogy, “paint” each of the major diseases affecting the central nervous system (CNS). This work concludes with a discussion of image artifacts and pitfalls in image interpretation, which, in spite our best efforts to minimize or eliminate them, continue to occur. Much of the ensuing discussion is based on our own institutional experience. Protocols, therefore, do not necessarily match those from other institutions due to variability in clinical emphasis, MR instruments, and available software. An attempt was made to focus on basic clinical sequences that are available on most modern MR systems, with protocols employing generally accepted clinical imaging philosophies. J. Magn. Reson. Imaging 2007;26:838–847. © 2007 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
It’s a high I never want to stop. Job I love, big money, fast cars. Good friends and fine women. Saving lives one brain at a time. I’ve got it all… Except the one treasure I can’t touch. Bella Garrett. For seven years she’s tortured me. Her smile, compassion, and a body that ki
## Abstract ## Purpose To describe a portable, easily assembled phantom with well‐defined bore geometry together with a series of tests that will form the basis of a standardized quality assurance protocol in a multicenter trial of flow measurement by the MR phase mapping technique. ## Materials