✦ Synopsis


Study design/materials and methods:

The aim of this experimental study was to investigate the effect of nd:yag laser on metallic tracheobronchial stents, because nd:yag laser could be used for resection of tumourous tissue growing through stent meshes (strecker-, palmaz-, wallstent).

Study design/materials and methods:

An in vitro worst-case-model was used to investigate the effects of different types of laser application on metallic stents: non-contact application, and contact application with bare fibres and with hemispherical sapphires.

Results:

In the non-contact method and with bare fibres stent destruction occurred at power settings exceeding 10 w, whereas in the contact method with hemispherical sapphires power settings of 20 w were possible without stent damage.


📜 SIMILAR VOLUMES


Effect of a modified Nd:YAG laser techni
✍ Menovsky, Thomas; Beek, Johan F.; Weerman, Marius van der Bergh; van Overbeeke, 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 243 KB 👁 2 views

## Background and Objectives : Traumatic transection of a peripheral nerve is inherently associated with the development of neuroma at the end of the proximal stump, often leading to therapyresistant pain. This study was designed to evaluate whether the neodymium:yttrium aluminum garnet (Nd:YAG) la

Detection of plasma produced in the inte
✍ Xiao-Wu Ni; Jian Lu; Zhong-Hua Shen; Jian-Ping Chen; Yi-Xin Zhang; Tuo Zhu 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 99 KB 👁 1 views

In this paper, the interaction process of a high-power Q-switched YAG laser and a metal᎐nitride᎐oxide᎐semiconductor ( ) ( ) MNOS -type charge-coupled de¨ice CCD is studied with the help of the plasma shape and structure under the repeated actions of laser pulses. Mach᎐Zehnder interferograms of plasm

Imaging Transport Disorder in Conducting
✍ J.L. Sample; K.C. Beverly; P.R. Chaudhari; F. Remacle; J.R. Heath; R.D. Levine 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 324 KB 👁 2 views

growth method be applied to the growth of nanowires made of other materials? These questions are the subject for further studies in our group. In conclusion, we discovered a new method for synthesizing long and highly ordered amorphous silicon oxide nanowires in bulk quantities. The length of the n

Intramedullary fixation of distal femora
✍ Viljanen, J. ;Kinnunen, J. ;Bondestam, S. ;Rokkanen, P. 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 179 KB 👁 1 views

Osteotomies of distal femoral diaphysis were fixed intramedullary with self-reinforced poly-L-lactide acid (SR-PLLA) rods in 19 and with metallic rods in 34 adult rabbits. The follow-up times were 8, 16, 24, and 48 weeks. Plain radiographs, computed tomography (CT), quantitative computed tomography