𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Multisite evaluation of a new dipstick for albumin, protein, and creatinine

✍ Scribed by Jane F. Wallace; Michael J. Pugia; John A. Lott; Karl E. Luke; Zak K. Shihabi; Michael Sheehan; Jean M. Bucksa


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
61 KB
Volume
15
Category
Article
ISSN
0887-8013

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The goal of our study was to perform a multisite evaluation of a new urine dipstick called Multistix PRO™ (Bayer, Elkhart, IN), which has reagent pads for the simultaneous assay of urinary albumin, protein, and creatinine. Patients’ urine specimens were assayed at four sites with these dipsticks and with the familiar Bayer Multistix® 10SG dipsticks for protein. The new dipstick pads for albumin are impregnated with bis (3′,3″‐diiodo‐4′,4″‐dihydroxy‐5′,5″‐dinitrophenyl)‐3,4,5,6‐tetrabromo‐sulfonephthalein (DIDNTB) dye. These dipsticks also have a novel pad that estimates urinary creatinine using the peroxidase activity of the copper‐creatinine complex. We determined the interlaboratory agreement of these dipsticks by comparing dipstick results to values obtained by quantitative analytical methods. We found that dividing the dipsticks’ albumin or protein results by the creatinine concentration reduced the number of false‐positive albumin or protein values observed in concentrated urines, and reduced the number of false negatives in dilute urines. The ratio of albumin to creatinine, or protein to creatinine gives a better measure of albumin or protein excretion. Compared to reading by eye, the dipstick results agreed better with the quantitative assays when they were read by a reflectometer (Bayer Clinitek). J. Clin. Lab. Anal. 15:231–235, 2001. © 2001 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Comparison of instrument-read dipsticks
✍ Michael J. Pugia; John A. Lott; Karl E. Luke; Zak K. Shihabi; Frank H. Wians Jr. 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 31 KB 👁 1 views

Three hospital sites evaluated the Bayer two-pad urine dipstick as a screening test for microalbuminuria. One pad estimates albumin concentrations between 10 and 150 mg/L, and the second estimates creatinine values between 300 and 3,000 mg/L. The Boehringer Mannheim (BMD) Micral® dipstick was also c

Evaluation of a dipstick method for the
✍ Claudio N. Beristain; L. Federico Rojkin; Dr. Luis E. Lorenzo 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 386 KB

Serology has been a fundamental tool to prevent post-transfusional infection with human immunodeficiency virus (HIV) and for epidemiological surveys, the first step to attempt control of the pandemia. Enzyme immunoassay is in widespread use. Nevertheless, simpler methods are needed in many countries

Development and implementation of a mult
✍ Julienne Giard; Karen Hennigan; Nicholas Huntington; Wendy Vogel; Debbie Rinehar 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 156 KB 👁 1 views

## Abstract In this article we describe the development and implementation of the Substance Abuse and Mental Health Services Administration's (SAMHSA's) multisite Women, Co‐Occurring Disorders and Violence Study (WCDVS), highlighting some of the challenges encountered, decisions made, and lessons l