Several pulse sequences which generate projected MR angiograms are presented. These pulse sequences exploit multiple-gradient refocused echoes to obtain several independent angiograms, which can be combined or separately analyzed to provide more information than an individual angiogram. For example, a series of angiograms, each with a different projection axis, can be obtained in the time required to obtain a single angiogram using a single-echo method. If the view angle of each echo is the same, then the acquired angiograms can be added to enhance the signal-to-noise ratio. Another pulse sequence simultaneously obtains two or more angiograms, sensitive to orthogonal flow components of the overall blood flow. These angiograms are then added to give an angiogram which is sensitive to flow in all directions.


๐Ÿ“œ SIMILAR VOLUMES


Pulmonary magnetic resonance angiography
โœ James F.M. Meaney; Lars O.M. Johansson; Hakan Ahlstrom; Martin R. Prince ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 840 KB
Ghost magnetic resonance angiography
โœ Ioannis Koktzoglou; Robert R. Edelman ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 213 KB

## Abstract Traditional methods for magnetic resonance angiography (MRA) involve the radiofrequency excitation of vascular spins within a selected region of tissue, followed by gradient localization and imaging of those spins within that same region. Signals that unfaithfully localize within the im

Time-resolved magnetic resonance angiogr
โœ C. L. Dumoulin; S. P. Souza; M. F. Walker; E. Yoshitome ๐Ÿ“‚ Article ๐Ÿ“… 1988 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 667 KB

A time-resolved phase contrast magnetic resonance angiography technique is described. This technique provides a series of angiograms obtained at different phases of the cardiac cycle. Such a series of angiograms can be used to evaluate blood flow dynamics. For example, turbulent flow in the regions

Rapid scan magnetic resonance angiograph
โœ C. L. Dumoulin; S. P. Souza; H. R. Hart ๐Ÿ“‚ Article ๐Ÿ“… 1987 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 556 KB

The change in phase of transverse spin magnetization induced by macroscopic spin motion in the direction of an applied magnetic field gradient is used to generate projection angiograms. The method can provide a quantitative measure of laminar and pulsatile flow. Cardiac synchronization is not requir

Targeted ROTational magnetic resonance a
โœ James W. Goldfarb ๐Ÿ“‚ Article ๐Ÿ“… 2007 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 800 KB

## Abstract An MR angiographic method is presented in which a rotating 2D slice is centered on and targets a region or vessel of interest. Collecting a series of slices rotating about the center of the targeted region yields projection data sufficient for the calculation of 3D volumetric data of th

Flow-independent magnetic resonance proj
โœ G. A. Wright; D. G. Nishimura; A. Macovski ๐Ÿ“‚ Article ๐Ÿ“… 1991 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 980 KB

The performance of current, flow-based sequences for imaging vasculature using MR is severely restricted in regions with inherently slow flow. We address this problem with a flow-independent imaging method. Specifically, we generate projection images of blood in the limbs while suppressing signal fr