𝔖 Bobbio Scriptorium
✦   LIBER   ✦

MR characterization of blood flow in native and grafted internal mammary arteries

✍ Scribed by Jörg F. Debatin; John A. Strong; H. Dirk Sostman; Rosa Negro-Vilar; Susan S. Paine; James M. Douglas Jr; Norbert J. Pelc


Publisher
John Wiley and Sons
Year
1993
Tongue
English
Weight
891 KB
Volume
3
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

In the postoperative patient with anginal symptoms, differentiation between bypass graft compromise and nonischemic causes has until now been accomplished only by means of x‐ray angiography. A noninvasive test is clearly desirable. The authors used a cine phase‐contrast (PC) magnetic resonance (MR) imaging technique to characterize blood flow in native and grafted internal mammary arteries (IMAs). Ten volunteers and 15 patients who had recently undergone IMA coronary artery bypass grafting were imaged. Cine PC MR imaging was performed in the transaxial plane at the level of the pulmonary artery bifurcation. Flow in both IMAs was quantified and expressed as a percentage of cardiac output measured in the ascending aorta. In the 15 patients, flow analysis was performed in both the native and grafted IMAs. In the volunteers, IMA blood flow ranged from 2.1% to 4.3% of cardiac output on the left (mean, 3.5%) and 2.1% to 5.1% (mean, 3.5%) on the right. There was considerable intersubject variability, with coefficients of variation of 10.7% for the left and 12.3% for the right IMA. Intrasubject variability was limited, with estimated common standard deviations of 0.45% of cardiac output (range, 0.2%–1.1%) for the left and 0.39% (range, 0.1%–0.6%) for the right IMA. Flow in grafted IMAs was identified in 13 of 15 patients. In one of two patients without demonstrable IMA graft flow, cardiac catheterization confirmed lack of flow. IMA graft flow varied from 28 to 164 mL/min (mean, 80.3 mL/min). This study shows the feasibility of using cine PC MR imaging as a quantitative method of evaluating blood flow in IMA coronary artery bypass grafts.


📜 SIMILAR VOLUMES


Breath-hold MR measurements of blood flo
✍ Hajime Sakuma; Sebastian Globits; Margaret O'sullivan; Ann Shimakawa; Matt A. Be 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 547 KB

## Breath -hold velocity-encoded cine M R (VENC-MR) im-aginS is a feasible method for measuring phasic blood flow velocity in small vessels that move during respiration. The purposes of the current study are to compare breathhold VENC-MR measurements of flow velocities in the internal mammary arte

Quantitative measurements of cerebral bl
✍ Weili Lin; Azim Celik; Colin Derdeyn; Hongyu An; Yueh Lee; Tom Videen; Leif Oste 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 535 KB

## Abstract Although it has been demonstrated that quantitative measures of cerebral blood flow (CBF) can be obtained with the singular value decomposition (SVD) algorithm, the extent to which quantitative CBF measurements can be utilized under pathophysiological conditions has not been systematica