𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Morphological studies on machined implants of commercially pure titanium and titanium alloy (Ti6Al4V) in the rabbit

✍ Scribed by Anders Palmquist; Fredrik Lindberg; Lena Emanuelsson; Rickard Brånemark; Håkan Engqvist; Peter Thomsen


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
538 KB
Volume
91B
Category
Article
ISSN
1552-4973

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The aim of this study was to evaluate the bone response to commercially pure titanium grade I and titanium alloy grade V (90% Ti, 6% Al, and 4% V, depicted Ti6Al4V) after 8 weeks in rabbit tibia. Interference microscopy and scanning electron microscopy were used for surface analyses. Transmission electron microscopy (TEM) was used for evaluation of surface crystallinity and chemistry after preparation of ultrathin sections using focused ion beam (FIB) microscopy. Three different embedding resins commonly used for histological preparation were evaluated with respect to adaptation to a turned implant surface. Epoxy Agar 100 resin and acrylic Technovit 7200 resin showed low separation while acrylic LR White resin showed large separation at the interface. The retrieved specimens were embedded in acrylic Technovit 7200 resin after fixation and dehydration. The histological evaluation revealed osseointegration for both c.p. titanium grade I and Ti6Al4V alloy, but no quantitative differences in bone contact and bone area were detected. Because a separation of implant and tissue occurred in the interface between implant and bone embedded in acrylic Technovit 7200 resin, additional factors related to implant surface properties and technical procedures are likely to influence the possibilities to prepare ultrathin sections by FIB. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009


📜 SIMILAR VOLUMES


Surface analysis and biocorrosion proper
✍ Maria C. Advincula; Don Petersen; Firoz Rahemtulla; Rigoberto Advincula; Jack E. 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 931 KB

## Abstract Surfaces of biocompatible alloys used as implants play a significant role in their osseointegration. Surface sol–gel processing (SSP), a variant of the bulk sol–gel technique, is a relatively new process to prepare bioreactive nanostructured titanium oxide for thin film coatings. The su

Osseointegration of hydroxyapatite-coate
✍ Oosterbos, C. J. M. ;Vogely, H. Ch. ;Nijhof, M. W. ;Fleer, A. ;Verbout, A. J. ;T 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 177 KB 👁 1 views

## Abstract A study was designed to investigate the osseointegration of titanium implants, either noncoated or coated with hydroxyapatite (HA), into rabbit tibiae in the presence of local infection compared with osseointegration in the absence of local infection. HA‐coated or noncoated Ti cylinders

Correlation between rate of bony ingrowt
✍ A. Oron; G. Agar; U. Oron; A. Stein 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 203 KB

## Abstract The rate of bony ingrowth to identical metal implants made of either pure titanium (cpTi), titanium alloy (Ti‐6Al‐4V), or stainless steel 316L (SS) inserted to the medullar canal of the femur in rats was investigated. The kinetics of spontaneous deposition of hydroxyapatite (HA) globule

The effect of scanning electrochemical p
✍ Mark T. Ehrensberger; Jeremy L. Gilbert 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 389 KB

## Abstract The electrochemical history (voltage–time variations) of titanium oxide‐solution interfaces can vary widely __in vivo__, particularly where oxide abrasion is present, and it is important to assess the effects of voltage on the impedance behavior of the interface. Potential step impedanc

The effect of static applied potential o
✍ Mark T. Ehrensberger; Jeremy L. Gilbert 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 203 KB

## Abstract Potential step impedance analysis was utilized to evaluate the electrochemical impedance of commercially pure titanium (cpTi) samples that were polarized to static potentials (range from −1000 mV to +1000 mV __vs__. Ag/AgCl) and immersed in physiologically relevant electrolytes [phospha

Prophylaxis of infection and effects on
✍ Dirk Jan F. Moojen; H. Charles Vogely; André Fleer; Peter G.J. Nikkels; Paul A. 📂 Article 📅 2009 🏛 Elsevier Science 🌐 English ⚖ 299 KB 👁 2 views

## Abstract No options are available for local antibiotic delivery from uncemented implants. By loading a porous titanium implant with a biomimetic HA‐coating (PeriApatite, PA) with antibiotics, we could obtain adequate local antibiotic concentrations and reduce infection susceptibility. This study