๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Monitoring the reactions of cisplatin with nucleotides and methionine by reversed-phase high-performance liquid chromatography using cationic and anionic pairing ions

โœ Scribed by Christopher M. Riley; Larry A. Sternson; Arnold J. Repta; Stephanie A. Slyter


Publisher
Elsevier Science
Year
1983
Tongue
English
Weight
818 KB
Volume
130
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

โœฆ Synopsis


Methodology, based on reversed-phase high-performance liquid chromatography, is described for monitoring the reactions of cisplatin with DNA, nucleotides, and methionine. Cisplatin was determined in DNA ultrafiltrates on solvent-generated anion exchangers which were prepared by coating the surface of a reversed-phase column with hexadecyltrimethylammonium bromide. These systems were also applicable to studies on the reactions of cisplatin with nucleotides. The retention of the nucleotides studied (S-AMP, S-GMP, S-CMP, and S-TMP) was described by means of an ion-exchange model and was manipulated by controlling the phosphate concentration in the mobile phase and its pH. The results indicate that cisplatin interacts predominantly with adenosine and guanosine groups on the DNA molecule and that binding is limited by the rate of conversion to an aquated intermediate. Whereas revetsed-phase HPLC systems employing cationic pairing ions were applicable to the analysis of mixtures containing cisplatin and anionic solutes, systems employing alkyl sulfonates were required to monitor the reaction of cisplatin with methionine which produces cationic products. Retention, in this latter system, was optimized by the addition of acetonitrile to the mobile phase and by controlling the concentration and chain length of alkylsulfonate in the mobile phase. Although an octadecylsilylsilica, reversedphase column was preferred for the analytical separation of the methionine-platinum complexes, a polystyrene-divinylbenzene colume was preferred for preparative work.


๐Ÿ“œ SIMILAR VOLUMES


Fluorometric determination of adenine nu
โœ Alfonso Ramos-Salazar; Andrew D. Baines ๐Ÿ“‚ Article ๐Ÿ“… 1985 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 389 KB

A sensitive and specific assay for measurement of adenine nucleotides and adenosine by paired-ion high-performance liquid chromatography is described. The I,N6-ethenoderivatives of ATP (c-ATP), ADP (+ADP), AMP (c-AMP). and adenosine (c-Ado), formed by reaction with chloroacetaldehyde at 37ยฐC. were s