𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Monitoring blood oxygen state in muscle microcirculation with transverse relaxation

✍ Scribed by J.A. Stainsby; G.A. Wright


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
265 KB
Volume
45
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Oxygen uptake from the microcirculation is a direct measure of tissue function. Magnetic resonance is capable of detecting differences between oxygenated and deoxygenated blood due to the paramagnetic properties of deoxyhemoglobin. At the level of the microcirculation, however, imaging methods cannot directly visualize the vessels. Instead, bulk MR parameters are investigated for their ability to monitor blood oxygen saturation (%O~2~) changes in the microcirculation of tissue, specifically skeletal muscle. Experiments in an in vitro model verified the feasibility of detecting changes in exponential decay signals, and also verified the prediction of only two distinct decay components. Experiments in a rabbit model demonstrate that T~2~′ and monoexponential T~2~ decay are not sensitive to blood oxygen changes, but that the long‐T~2~ component in a biexponential fit is correlated to the blood oxygen state. Assuming a two‐pool model for water protons in muscle, and with knowledge of the T~2~‐%O~2~ relation, estimates of the microcirculation blood oxygen state can be made with some reasonable assumptions. Magn Reson Med 45:662–672, 2001. © 2001 Wiley‐Liss, Inc.