## Abstract Quantitative analysis of contrast‐enhanced dynamic MR images has potential for diagnosing prostate cancer. Contemporary fast acquisition techniques can give sufficiently high temporal resolution to sample the fast dynamics observed in the prostate. Data reduction for parametric visualiz
Model-based blind estimation of kinetic parameters in dynamic contrast enhanced (DCE)-MRI
✍ Scribed by Jacob U. Fluckiger; Matthias C. Schabel; Edward V.R. DiBella
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 666 KB
- Volume
- 62
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A method to simultaneously estimate the arterial input function (AIF) and pharmacokinetic model parameters from dynamic contrast‐enhanced (DCE)‐MRI data was developed. This algorithm uses a parameterized functional form to model the AIF and k‐means clustering to classify tissue time‐concentration measurements into a set of characteristic curves. An iterative blind estimation algorithm alternately estimated parameters for the input function and the pharmacokinetic model. Computer simulations were used to investigate the algorithm's sensitivity to noise and initial estimates. In 12 patients with sarcomas, pharmacokinetic parameter estimates were compared with “truth” obtained from model regression using a measured AIF. When arterial voxels were included in the blind estimation algorithm, the resulting AIF was similar to the measured input function. The “true” K^trans^ values in tumor regions were not significantly different than the estimated values, 0.99 ± 0.41 and 0.86 ± 0.40 min^−1^, respectively, P = 0.27. “True” k~ep~ values also matched closely, 0.70 ± 0.24 and 0.65 ± 0.25 min^−1^, P = 0.08. When only tissue curves free of significant vascular contribution are used (v~p~ < 0.05), the resulting AIF showed substantial delay and dispersion consistent with a more local AIF such as has been observed in dynamic susceptibility contrast imaging in the brain. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose: To quantify B~1~ transmission‐field inhomogeneity in breast imaging of normal volunteers at 3T using 3D T~1~‐weighted spoiled gradient echo and to assess the resulting errors in enhancement ratio (ER) measured in dynamic contrast‐enhanced MRI (DCE‐MRI) studies of the breast
## Abstract Cervical tumors of 38 cervix cancer patients were scanned by __T__~1~‐weighted dynamic contrast enhanced (DCE) MRI and then by DCE‐CT on the same day. Gadodiamide and iohexol were respectively used as the low‐molecular‐weight contrast agent in DCE‐MRI and DCE‐CT. Under an extended Tofts