Peripheral circulation in the newborn: I
โ
O. Linderkamp; I. Strohhacker; H. T. Versmold; H. Klose; K. P. Riegel; K. Betke
๐
Article
๐
1978
๐
Springer
๐
English
โ 534 KB
Peripheral blood flow and systolic blood pressure (strain-gauge plethysmograph), blood volume (Evans blue) and whole blood viscosity (cone-plate viscometer) have been measured in 66 premature and full-term infants 6 to 144h of age. Blood flow and blood volume were moderately decreased in the infants